The present work aimed to investigate the feasibility of using stable isotopes and inductively-coupled plasma mass spectrometry (ICP/MS) to study Mg absorption in rats. Male Wistar rats, aged 7 weeks and weighing 180 g, were used. They were fed on a semi-purified diet containing 1070 mg Mg/kg, and had free access to feed and distilled water. In the first experiment, after a 16 d adaptation period, two doses of enriched 25Mg (6 and 12 mg) were administered by oral intubation, faeces and urine were collected daily and blood was sampled. Isotope ratios were determined by ICP/MS. 'True' absorption values, using the faecal isotope data, were 0.63 and 0.56 in rats receiving 6 and 12 mg 25Mg respectively, while apparent absorption was 0.50 for two successive periods of metabolic balance studies. Moreover, the oral isotope administration resulted in a measurable isotopic enrichment in plasma within hours which was still detectable on the third day following the isotope administration. In the second experiment, investigating the double labelling technique, similar rats were dosed simultaneously with 5 mg 26Mg orally (premixed with diet) and 0.29 mg 25Mg intravenously. The calculated Mg true absorption values were very similar when calculated from blood or urine data (0.38) but were lower than that obtained from faecal data (0.50). The possible causes of such an unexpected difference and limits of the double labelling technique for Mg absorption are discussed here. Together these results indicate that although 25Mg and 26Mg isotopes have high natural abundance, the described methodology permits meaningful investigations of Mg bioavailability and metabolism.
منابع مشابه
Determination of 137Ba Isotope Abundances in Water Samples by Inductively Coupled Plasma-optical Emission Spectrometry Combined with Least-squares Support Vector Machine Regression
A simple and rapid method for the determination of 137Ba isotope abundances in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES) coupled with least-squares support vector machine regression (LS-SVM) is reported. By evaluation of emission lines of barium, it was found that the emission line at 493.408 nm provides the best results for the determination...
متن کاملHigh‐precision determination of lithium and magnesium isotopes utilising single column separation and multi‐collector inductively coupled plasma mass spectrometry
RATIONALE Li and Mg isotopes are increasingly used as a combined tool within the geosciences. However, established methods require separate sample purification protocols utilising several column separation procedures. This study presents a single-step cation-exchange method for quantitative separation of trace levels of Li and Mg from multiple sample matrices. METHODS The column method utilis...
متن کاملSelective Separation and Preconcentration of trace Amounts of Gallium in Water and Rice Samples using Cloud Point Extraction and Determination by Inductively Coupled Plasma-Atomic Emission Spectrometry
In the present study a cloud-point extraction process using non-ionic surfactant Triton X-114 for selective extraction of gallium from aqueous solutions was developed. The method is based on the complex formation of Ga (III) with N, N′ -bis (salycilidene)-1, 2-phenylenediamine (salophen) as a chelating agent in buffer media of pH 5. After phase separation and dilution of the surfactant-rich pha...
متن کاملMicrowave assisted digestion coupled with inductively coupled plasma optical emission spectrometry for determining element concentrations in halophytes
Introduction: This study was carried out to determine elements (Li, Na, K, Mg, Ca, Ba, B, Al, Si, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Ag and P) in the Suaeda vermiculata (S. vermiculata) and Suaeda aegyptiaca (S. aegyptiaca) in three different regions of Southern Iran using inductively coupled plasma optical emission spectrometry (ICP-OES) after microwave-assisted acid digestion. Materials and ...
متن کاملSynergistic cellular toxicity and uptake effects of iodixanol conjugated to anionic linear globular dendrimer G2
Objective(s): Early diagnosis of cancer using noninvasive imaging techniques has been discussed in several recent studies. The present study aimed to assess the synergistic effects of iodixanol-conjugated polyethylene glycol (PEG)-citrate (anionic linear globular) dendrimer G2 on MCF-7 breast cancer cells and human embryonic kidney 293 (HEK293) cells. Materials and Methods: PEG-citrate de...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of nutrition
دوره 77 6 شماره
صفحات -
تاریخ انتشار 1997