Nonlinear analysis of arterial oscillated flow in experimental stenosis and microsurgical anastomosis.

نویسندگان

  • P May
  • O Gerbault
  • C Arrouvel
  • M Revol
  • J M Servant
  • E Vicaut
چکیده

BACKGROUND Thrombotic vascular occlusion is one of the main complications that can occur during microsurgical anastomosis and is frequent when the blood becomes turbulent. The aim of this ex vivo study was to test the use of nonlinear mathematical tools to detect turbulence flow upstream and downstream of an arterial stenosis and of a microsurgical anastomosis technique in arteries with diameters in the range of microsurgical practice. MATERIALS AND METHODS Rat carotid arteries (0.8 to 1.2 mm diameter) were transferred to a flow chamber and perfused with Krebs solution. An oscillated vascular flow was initiated with a peristaltic pump and a transit time flowmeter was used to measure flow with two probes. An arterial stenosis was created by a ligature and progressively increased ranging from 0 to 95%. For each flow signal three nonlinear analytical procedures were applied: time-delayed procedures, correlation dimension, and computing of the largest Lyapunov exponent. RESULTS Our results indicated that the level of turbulence flow is correlated with the area reduction stenosis. In the range of 60-95% area reduction stenosis, we noted an experimental increase of turbulence flow. We also founded that a classical end-to-end anastomosis technique induced an increase of the turbulence flow in comparison with a control artery. CONCLUSIONS Thus nonlinear analysis can be useful in characterizing the complexity of an oscillated flow in small arteries submitted to stenosis or microsurgical anastomosis and may have clinical uses in detecting high level turbulent flow after microsurgery.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

گزارش یک مورد آنژیوپلاستی و Stent گذاری موفق در درمان تنگی

    Introduction: Renal transplantation has established itself as the treatment of choice for the majority of patients with End stage renal failure(ESRF). Arterial stenosis is the most common vascular complication after kidney transplantation, occurring in approximately 4%-25% of transplant recipients. Case Report: The patient is a 68 year old man with ESRF due to Poly cystic kidney disease(PCK...

متن کامل

Microsurgical Training Curriculum for Neurosurgery Residents in Southern Iran

Training of microvascular anastomosis techniques comprise the major part of surgical skills, necessary for revascularization surgeries. Training can be performed in several stages based on the experience of trainees. This should mainly start with various models of artificial materials that simulate tissues. In the next stage, trainee should practice microsurgical skill on a non-living tissue mo...

متن کامل

Newtonian and Non-Newtonian Blood Flow Simulation after Arterial Stenosis- Steady State and Pulsatile Approaches

Arterial stenosis, for example Atherosclerosis, is one of the most serious forms of arterial disease in the formation of which hemodynamic factors play a significant role. In the present study, a 3-D rigid carotid artery with axisymmetric stenosis with 75% reduction in cross-sectional area is considered. Laminar blood flow is assumed to have both Newtonian and non-Newtonian behavior (generalize...

متن کامل

Numerical Study of Hemodynamic Wall Parameters on Pulsatile Flow through Arterial Stenosis

In this paper hemodynamic wall parameters which play an important role to diagnose arterial disease were studied and compared for three different rheology models (Newtonian, Power law and Quemada). Also because of the pulsatile behavior of blood flow the results were obtained for three Womersley numbers which represent the frequencies of the applied pulses. Results show that Quemada model alway...

متن کامل

A Numerical Analysis for the Effect of Slip Velocity and Stenosis Shape on Non-Newtonian Flow of Blood (TECHNICAL NOTE)

The aim of this paper is to study the effect of slip velocity and shape of stenosis on non-Newtonian flow of blood through a stenosed arterial segment. Blood is modeled as Bingham-Plastic fluid in a uniform circular tube with a radially non-symmetric stenosis. The problem is investigated by a joint effort of analytical and numerical techniques. The influence of stenosis shape parameter, slip ve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of surgical research

دوره 99 1  شماره 

صفحات  -

تاریخ انتشار 2001