Evaluation of the AutoSCAN-3, a device for reading microdilution trays.
نویسندگان
چکیده
The AutoSCAN-3 (American MicroScan, Mahwah, N.J.) is an instrument capable of automated reading of commercially available microdilution trays for identification and quantitative susceptibility testing of rapidly growing bacteria. This study compared the results of visual and automated reading of microdilution trays for determination and interpretation of minimum inhibitory concentrations of 471 selected gram-negative and gram-positive clinical bacterial isolates. Visual and automated readings were performed in a double-blind fashion, and all discrepancies were examined by a referee. A quantitative comparison of minimum inhibitory concentrations was performed for 201 organisms, yielding 2,472 drug-organism combinations. After exclusion of off-scale values, complete quantitative agreement was obtained in 94% of 959 on-scale combinations, and agreement within +/- 1 well was obtained in 99.3%. Considering the minimum inhibitory concentration interpretations routinely furnished by the instrument, a qualitative comparison was performed for all 471 organisms. Complete agreement in interpretation was obtained in 97.6% of 5,843 drugs-organism combinations, with very major discrepancies accounting for only 0.1% and major discrepancies accounting for 0.2% of all combinations tested.
منابع مشابه
Preliminary evaluation of the autoSCAN-3, an instrument for automated reading an interpretation of microdilution trays: identification of aerobic gram-negative bacilli.
The autoSCAN-3, an instrument for the automated reading and interpretation of Microscan microdilution trays, was evaluated for its ability to identify gram-negative bacilli. The results obtained by the visual reading of microdilution trays were compared with the results obtained with the machine. A total 387 clinical isolates of Enterobacteriaceae and nonfermenters were compared by both methods...
متن کاملautoSCAN-4 system for identification of gram-negative bacilli.
A production model of the autoSCAN-4 system (American MicroScan, Inc., Mahwah, N.J.) was tested with not more than 11 strains each of 73 groups or species of gram-negative bacilli from various Centers for Disease Control culture collections. The strains included typical and atypical strains of enteric fermenters, nonenteric fermenters, and nonfermenters. The autoSCAN-4 system identified 95.3% o...
متن کاملANTIMICROBIAL AGENTs
Micro-Media Systems (MMS) has developed a procedure by which microdilution trays can be filled with dilutions of antimicrobial agents, frozen, and distributed to clinical laboratories. The trays are prepared in various distribution centers throughout the United States to supply clinical laboratories in the vicinity of each center. For use, trays are removed from the freezer, allowed to thaw, an...
متن کاملShort-term storage of six penicillins and cephalothin in microdilution trays for antimicrobial susceptibility tests.
To perform microdilution antimicrobial susceptibility tests efficiently, broth dilutions of the antimicrobial drugs should be prepared in large batches and stored frozen until needed. Studies were carried out to document the stability of ampicillin, benzylpenicillin, carbenicillin, methicillin, oxacillin, nafcillin, and cephalothin in microdilution trays during storage at -20 and -60 C. No sign...
متن کاملEvaluation of the MicroScan Rapid Yeast Identification panel.
The MicroScan Rapid Yeast Identification (RYI) panel is a 4-h microdilution system for identification of clinical yeastlike isolates. Its accuracy was evaluated by using 357 isolates encompassing 11 genera and 30 species. The RYI panel identifications were compared with those obtained by the API 20C system assisted with morphological characterization on cornmeal-Tween 80 agar. The panels were r...