Effect of a urinary catheter on seed position and rectal and bladder doses in CT-based post-implant dosimetry for prostate cancer brachytherapy

نویسندگان

  • Hiroaki Kunogi
  • Nanae Yamaguchi
  • Yoshiaki Wakumoto
  • Keisuke Sasai
چکیده

PURPOSE To assess the variability in rectal and bladder dosimetric parameters determined according to post-implant computed tomography (CT) images in patients with or without a urethral catheter. MATERIAL AND METHODS Patients with prostate cancer who were scheduled to undergo CT after brachytherapy between October 2012 and January 2014 were included. We obtained CT series with and without a urinary catheter in each patient. We compared the rectal and bladder doses in 18 patients on each CT series. RESULTS The shifts in the seed positions between with and without a catheter in place were 1.3 ± 0.3 mm (mean ± standard deviation). The radiation doses to the rectum, as determined on the CT series, with a urethral catheter were higher than those on CT without a catheter (p < 0.001). Radiation doses to the bladder with a catheter were significantly lower than those without a catheter (p = 0.027). CONCLUSIONS Post-implant dosimetry (PID) with no catheter showed significantly lower rectal doses and higher bladder doses than those of PID with a catheter. We recommend the PID procedure for CT images in patients without a catheter. Use of CT with a catheter is limited to identifying urethral position.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conformal prostate brachytherapy guided by realtime dynamic dose calculations using permanent 125iodine implants: technical description and preliminary experience.

OBJECTIVE Low dose rate (LDR) prostate brachytherapy (permanent 125I or 103Pd seeds) is an accepted treatment option for low risk prostate cancer patients. However, differences in prostate spatial location, volume and gland deformation between the images obtained during pre-planning and later on during the implant procedure prevent the pre-planned intended dose to be accurately delivered. We ar...

متن کامل

Dosimetric effects of prone and supine positions on post-implant assessments for prostate brachytherapy

PURPOSE Post-implant dosimetric assessment is essential for optimal care of patients receiving prostate brachytherapy. In most institutions, post-implant computed tomography (CT) is performed in the supine position. This study aimed to assess variability in dosimetric parameters with postural changes during acquisition of post-implant CT scans. MATERIAL AND METHODS In total, 85 consecutive pa...

متن کامل

Prostate cancer treated with brachytherapy; an exploratory study of dose-dependent biomarkers and quality of life

BACKGROUND Low-dose-rate permanent prostate brachytherapy (PPB) is an attractive treatment option for patients with localised prostate cancer with excellent outcomes. As standard CT-based post-implant dosimetry often correlates poorly with late treatment-related toxicity, this exploratory (proof of concept) study was conducted to investigate correlations between radiation - induced DNA damage b...

متن کامل

The effects of volumetric changes on radiation doses of the rectum and bladder during radiotherapy in patients with prostate cancer

Background: In prostate radiotherapy, changes in the volume of the bladder and rectum can influence dose delivery. In this study, cone-beam computerised tomography (CBCT) imaging was used to assess volumetric, and corresponding radiation dosimetric changes, for the bladder and rectum in patients with prostate cancer treated using VMAT. Materials and Methods: Treatment planning computed tomograp...

متن کامل

Narrow safety range of intraoperative rectal irradiation exposure volume for avoiding bleeding after seed implant brachytherapy

BACKGROUND & PURPOSE Rectal toxicity is less common after 125I seed implant brachytherapy for prostate cancer, and intraoperative rectal dose-volume constraints (the constraint) is still undetermined in pioneering studies. As our constraint failed to prevent grade 2 or 3 rectal bleeding (bled-pts) in 5.1% of patients, we retrospectively explored another constraint for the prevention of rectal b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2015