Enhanced refocusing of fat signals using optimized multipulse echo sequences.
نویسندگان
چکیده
Endogenous magnetic resonance contrast based on the localized composition of fat in vivo can provide functional information. We found that the unequal pulse timings of the Uhrig's dynamical decoupling multipulse echo sequences significantly alter the signal intensity compared to conventional, equal-spaced Carr-Purcell-Meiboom-Gill sequences. The signal increases and decreases depending on the tissue and sequence parameters, as well as on the interpulse spacings; particularly strong differences were observed in fatty tissues, which have a highly structured morphology and a wide range of chemical shifts and J-couplings. We found that the predominant mechanism for fat refocusing under multipulse echo sequences is the chemical structure, with stimulated echoes playing a pivotal role. As a result, specialized pulse sequences can be designed to optimize refocusing of the fat chemical shifts and J-couplings, where the degree of refocusing can be tailored to specific types of fats. To determine the optimal time delays, we simulated various Uhrig dynamical decoupling and Carr-Purcell-Meiboom-Gill pulse sequence timings, and these results are compared to experimental results obtained on excised and in vivo fatty tissue. Applications to intermolecular multiple quantum coherence imaging, where the improved echo refocusing translates directly into signal enhancements, are presented as well.
منابع مشابه
"Spin-echo Like T1 Contrast" Volumetric Black-Blood Images Using 3D LOWRAT: Low Refocusing Flip Angle TSE
Introduction: T1 contrast is typically acquired using multi-slice two-dimensional spin-echo (2D SE), inversion recovery fast spin echo (T1 fluid-attenuated inversion recovery : T1FLAIR) or 3D T1-weighted spoiled gradient-echo (3D T1TFE) imaging [1]. However, these conventional methods have problems when used for contrast enhancement studies. 2D-SE requires long scan time for 3-plane diagnosis, ...
متن کاملEfficient fat suppression by slice-selection gradient reversal in twice-refocused diffusion encoding
Most diffusion imaging sequences rely on single-shot echo-planar imaging (EPI) for spatial encoding since it is the fastest acquisition available. However, it is sensitive to chemical-shift artifacts due to the low bandwidth in the phase-encoding direction, making fat suppression necessary. Often, spectral-selective RF pulses followed by gradient spoiling are used to selectively saturate the fa...
متن کاملReliable Cortical Thickness Estimation with Reduction of Susceptibility-Induced Signal Loss using Optimized T1-Weighted Single-Slab 3D Turbo Spin Echo Pulse Sequence
Introduction: In brain volumetry, magnetization-prepared rapid gradient recalled echo (MP-RAGE) imaging [1], which yields a strong T1-weighted contrast among brain tissues and thus a highly accurate segmentation of the brain structures, has been widely used. However, since signals in MPRAGE result from free induction decay (FID) without radio-frequency (RF) pulse induced refocusing, conventiona...
متن کاملFaster fat-water imaging with a novel multislice time-shifted GRASE-Dixon sequence
Introduction Recently, the gradientand spin-echo (GRASE) technique has been used to increase efficiency in Dixon fat-water imaging [1,2]. In these sequences, oscillating gradient lobes are carefully positioned between spin refocusing pulses to acquire multiple echoes with the necessary fat-water phase shifts. As it is necessary to collect at least two echoes with approximately π fat-water phase...
متن کاملNon-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)
Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different and weighting for liver fat quantification in patients with...