Assessment of body composition by air-displacement plethysmography: influence of body temperature and moisture

نویسندگان

  • David A Fields
  • Paul B Higgins
  • Gary R Hunter
چکیده

BACKGROUND: To investigate the effect of body temperature and moisture on body fat (%fat), volume and density by air-displacement plethysmography (BOD POD). METHODS: %fat, body volume and density by the BOD POD before (BOD PODBH) and immediately following hydrostatic weighing (BOD PODFH) were performed in 32 healthy females (age (yr) 33 +/- 11, weight (kg) 64 +/- 14, height (cm) 167 +/- 7). Body temperature and moisture were measured prior to BOD PODBH and prior to BOD PODFH with body moisture defined as the difference in body weight (kg) between the BOD PODBH and BOD PODFH measurements. RESULTS: BOD PODFH %fat (27.1%) and body volume (61.5 L) were significantly lower (P </= 0.001) and body density (1.0379 g/cm3) significantly higher (P </= 0.001) than BOD PODBH %fat (28.9%), body volume (61.7 L), and body density (1.0341 g/cm3). A significant increase in body temperature (~0.6 degrees C; P </= 0.001) and body moisture (0.08 kg; P </= 0.01) were observed between BOD PODBH and BOD PODFH. Body surface area was positively associated with the difference in %fat independent of changes in body temperature and moisture, r = 0.30, P < 0.05. CONCLUSION: These data demonstrate for the first time that increases in body heat and moisture result in an underestimation of body fat when using the BOD POD, however, the precise mechanism remains unidentified.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment and prediction of thoracic gas volume in pregnant women: an evaluation in relation to body composition assessment using air displacement plethysmography.

Assessment of body fat (BF) in pregnant women is important when investigating the relationship between maternal nutrition and offspring health. Convenient and accurate body composition methods applicable during pregnancy are therefore needed. Air displacement plethysmography, as applied in Bod Pod, represents such a method since it can assess body volume (BV) which, in combination with body wei...

متن کامل

Body composition assessment in extreme obesity and after massive weight loss induced by gastric bypass surgery.

Body composition methods were examined in 20 women [body mass index (BMI) 48.7 +/- 8.8 kg/m(2)] before and after weight loss [-44.8 +/- 14.6 (SD) kg] after gastric bypass (GBP) surgery. The reference method, a three-compartment (3C) model using body density by air displacement plethysmography and total body water (TBW) by H(2)18O dilution (3C-H(2)18O), showed a decrease in percent body fat (%BF...

متن کامل

Whole body air displacement plethysmography compared with hydrodensitometry for body composition analysis.

AIMS To assess the acceptability and feasibility of whole body air displacement plethysmography in children and to determine its precision and agreement with hydrodensitometry, an appropriate reference method. METHODS Age specific two component model equations were used to predict fat mass from body density in 22 children aged 8-12 years and in 10 adults for comparison of methods. Precision f...

متن کامل

Evaluation of a new pediatric air-displacement plethysmograph for body-composition assessment by means of chemical analysis of bovine tissue phantoms1–3

Background: Body-composition assessment reflects infant growth and nutritional status but is limited by practical considerations, accuracy, and safety. Objective: This study evaluated the precision and accuracy of a new air-displacement plethysmography (ADP) system for pediatric body-composition assessment. Design: We used 24 phantoms constructed from bovine lean muscle and fat. The phantoms va...

متن کامل

Comparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults.

BACKGROUND Over the past decade, considerable attention has been paid to accurately measuring body composition in diverse populations. Recently, the use of air-displacement plethysmography (AP) was proposed as an accurate, comfortable, and accessible method of body-composition analysis. OBJECTIVE The purpose of this study was to compare measurements of percentage body fat (%BF) by AP and 2 ot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Dynamic medicine : DM

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2004