The Radiation Exposure of Radiographer Related to the Location in C-arm Fluoroscopy-guided Pain Interventions

نویسندگان

  • Young Jae Chang
  • Ah Na Kim
  • In Su Oh
  • Nam Sik Woo
  • Hae Kyoung Kim
  • Jae Hun Kim
چکیده

BACKGROUND Although a physician may be the nearest to the radiation source during C-arm fluoroscope-guided interventions, the radiographer is also near the fluoroscope. We prospectively investigated the radiation exposure of radiographers relative to their location. METHODS The effective dose (ED) was measured with a digital dosimeter on the radiographers' left chest and the side of the table. We observed the location of the radiographers in each procedure related to the mobile support structure of the fluoroscope (Groups A, M and P). Data about age, height, weight, sex, exposure time, radiation absorbed dose (RAD), and the ED at the radiographer's chest and the side of the table was collected. RESULTS There were 51 cases for Group A, 116 cases for Group M and 144 cases for Group P. No significant differences were noted in the demographic data such as age, height, weight, and male to female ratio, and exposure time, RAD and ED at the side of the table. Group P had the lowest ED (0.5 ± 0.8 µSv) of all the groups (Group A, 1.6 ± 2.3 µSv; Group M, 1.3 ± 1.9 µSv; P < 0.001). The ED ratio (ED on the radiographer's chest/ED at the side of the table) of Group A was the highest, and the ED radio of Group P was the lowest of all the groups (Group A, 12.2 ± 21.5%; Group M, 5.7 ± 6.5%; Group P, 2.5 ± 6.7%; P < 0.001). CONCLUSIONS Radiographers can easily reduce their radiation exposure by changing their position. Two steps behind the mobile support structure can effectively decrease the exposure of radiographers by about 80%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

BACKGROUND The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. METHODS In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter ...

متن کامل

Factors Related to Radiation Exposure during Lumbar Spine Intervention

Fluoroscopy guidance is useful to confirm anatomical landmark and needle location for spine intervention; however, it can lead to radiation exposure in patients, physicians, and medical staff. Physicians who used fluoroscopy should be cognizant of radiation exposure and intend to minimize radiation dose. We retrospectively reviewed three lumbar spine intervention procedures (nerve root block, m...

متن کامل

Radiation exposure during percutaneous nephrolithotomy; Is there a risk of the patient and the operating team?

Background: The aim of this study was to calculate the radiation amount exposed during percutaneous nephrolithototomy (PCNL) and to make the urologists and other staff sensitive about the radiation risk they were exposed to. Materials and Methods: We measured the radiation exposure during 114 cases of PCNL performed. Thermoluminescent dosimeters (TLD) were placed between the operation table and...

متن کامل

Radiographer Delivered Fluoroscopy Reduces Radiation Exposure During Endoscopic Urological Procedures

INTRODUCTION The 1999 Ionising Radiation Regulations recommend that medical professionals using ionising radiation should aim to keep exposure as 'low as reasonably practicable'. Urologists regularly use fluoroscopy during endoscopic surgical procedures. In some institutions, this is delivered by a radiographer whereas in others, it is delivered by the urological surgeon. OBJECTIVES To determ...

متن کامل

Radiation Safety and Education in the Applicants of the Final Test for the Expert of Pain Medicine

BACKGROUND The C-arm fluoroscope is known as the most important equipment in pain interventions. This study was conducted to investigate the completion rate of education on radiation safety, the knowledge of radiation exposure, the use of radiation protection, and so on. METHODS Unsigned questionnaires were collected from the 27 pain physicians who applied for the final test to become an expe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 27  شماره 

صفحات  -

تاریخ انتشار 2014