Retrograde transcatheter closure of ventricular septal defect with Amplatzer Duct Occluder II

نویسندگان

  • Brina Suligoj
  • Natasa Cernic
  • Metka Zorc
  • Marko Noc
  • Saibal Kar
چکیده

One of the most feared complications of transcatheter closure of a perimembranous ventricular septal defect (VSD) by the Amplatzer membranous occluder is atrioventricular (AV) block, occurring in 3% to 20% of cases [1, 2]. Atrioventricular block may occur immediately due to squeezing effects of disks or late due to device-induced inflammation and fibrous tissue formation [3]. We herein describe a 14-year-old girl in whom an alternative method with the softer Amplatzer Duct Occluder, which may overcome the above limitations, was used. The indication for VSD closure was based on left ventricular volume overload documented by transthoracic echocardiography (TTE) and the fact that she wanted to continue with professional sport activity. The procedure was performed under general anesthesia with fluoroscopic and transesophageal echocardiography (TEE) guidance. Ventricular septal defect was confirmed by left ventriculography (Figure 1 A) and TEE assessing the interventricular septum in multiple planes. The largest VSD diameter was 5 mm, and the distance from the upper VSD margin to the aortic valve was 13 mm (Figure 1 B). Since the VSD diameter was < 6.5 mm and the distance between the upper margin and aortic valve was > 3 mm, closure with Amplatzer Duct Occluder II (ADO II, St. Jude Medical, St. Paul, Minnesota, USA) was selected [4, 5]. A 6 Fr JR 4 guiding catheter (Launcher, Medtronic Inc, Minneapolis) was advanced from the right femoral artery to the left side of the VSD, which was crossed by angled Terumo wire (Terumo Corporation, Tokyo, Japan). The guiding catheter was slowly advanced across the VSD to the right ventricle and loaded with the ADO II 6/6 mm attached to a 5 Fr TorqVue LP (St. Jude Medical, St. Paul, Minnesota, USA). The right retention disk was deployed and the assembly withdrawn so that the disk was aligned with the septum. The waist and left retention disk were then sequentially deployed. Once a stable position and no interference with aortic and tricuspid valves were confirmed with TEE, the delivery system was detached and removed together with the guiding catheter. Left ventriculography showed minimal intra-device residual shunting (Figure 1 C). Transthoracic echocardiography revealed both retention disks to be flat and in an appropriate position without interference with the aortic valve (Figure 1 D). The fluoroscopy time was 5.26 min. The postprocedural course was uneventful. After 49 days, TTE revealed good device position without residual shunt. Left ventricular end diastolic diameter decreased from 48 to 44 mm, left ventricular volume index from 65 to 51 ml/m2 and left atrial surface area from 20 to 14 cm2 compared to measurements before closure. After > 2 years, the patient continues to be in good condition without AV conduction block. In conclusion, we believe that retrograde closure of the membranous VSD with the ADO II should be considered if the diameter of the VSD, its morphology and the distance from the aortic valve documented by TEE are within the recommended range [4]. The procedure is substantially less invasive and faster than standard closure with the membranous Amplatz VSD occluder, without the need for an AV loop.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of aortopulmonary window with Amplatzer duct occluder II

Sir, An aortopulmonary window (APW) is a rare cardiac malformation, first reported by Elliotson, is found in 0.1% of patients with congenital cardiac lesions.[1] In most cases, surgical repair is undertaken during infancy although isolated cases have been reported of transcatheter device closures. We report our experience of transcatheter APW closure via antegrade and retrograde methods using a...

متن کامل

Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with...

متن کامل

Transcatheter Closure of a Muscular Ventricular Septal Defect By Amplatzer Ductal Occluder II

Ventriküler septal defektler transkateter tedavide kapatılması gereken bir defekt olarak görülmektedir. Son yıllarda yeni cihazların bulunması ile birçok merkezde ventriküler septal defektlerin perkütan kapatılması cesaretlendiren sonuçlarla uygulanmaktadır. Amplatzer oklüder sistemlerin son yıllarda kullanılmaya başlaması ile birlikte implantasyon sayılarında artma olmuştur. Bunun yanısıra, mü...

متن کامل

[Transcatheter closure of postinfarction ventricular septal defects using Amplatzer devices].

We carried out transcatheter procedures to close postinfarction ventricular septal defects (PIVSDs) in 19 patients: two had recanalization after surgical closure, and 17 had a primary PIVSD. In three of the latter patients, who had acute PIVSDs, the procedure was carried out in the first 3 weeks after infarction; in the 13 patients with subacute PIVSD, it was carried out 3.5-12 weeks after infa...

متن کامل

Transcatheter Closure of Perimembranous Ventricular Septal Defects With Amplatzer Duct Occluders.

Inroduction: This study reports on our experience with transcatheter closure of perimembraneous ventricular septal defects (pm-VSDs) with Amplatzer duct occluder I (ADO I) and Amplatzer duct occluder II (ADO II) Methods: Transcatheter device implantation with ADO I and ADO II was attempted in 17 patients with pm-VSD between August 2014 to December 2015. We usually decided the appropriate type a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2016