cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme

نویسندگان

  • Jinhun Joung
  • Robert S. Miyaoka
  • Thomas K. Lewellen
چکیده

Objective: Detector designs for small animal scanners are currently dominated by discrete crystal implementations. However, given the small crystal cross-sections required to obtain very high resolution, discrete designs are typically expensive, have low packing fraction, reduced light collection, and are labor intensive to build. To overcome these limitations we have investigated the feasibility of using a continuous miniature crystal element (cMiCE) detector module for high resolution small animal PET applications. Methods: The detector module consists of a single continuous slab of LSO, 25 25mm in exposed cross-section and 4mm thick, coupled directly to a PS-PMT (Hamamatsu R5900-00-C12). The large area surfaces of the crystal were polished and painted with TiO2 and the short surfaces were left unpolished and painted black. Further, a new statistics based positioning (SBP) algorithm has been implemented to address linearity and edge effect artifacts that are inherent with conventional Anger style positioning schemes. To characterize the light response function (LRF) of the detector, data were collected on a coarse grid using a highly collimated coincidence setup. The LRF was then estimated using cubic spline interpolation. Detector performance has been evaluated for both SBP and Anger based decoding using measured data and Monte Carlo simulations. Results: Using the SBP scheme, edge artifacts were successfully handled. Simulation results show that the useful field of view (UFOV) was extended to B22 22mm with an average point spread function of B0.5mm full width of half maximum (FWHMPSF). For the same detector with Anger decoding the UFOV of the detector was B16 16mm with an average FWHMPSP of B0.9mm. Experimental results yielded similar differences between FOV and resolution performance. FWHMPSF for the SBP and Anger based method was 1.4 and 2.0mm, uncorrected for source size, with a 1mm diameter point source, respectively. Conclusion: A continuous detector module with an average FWHMPSF approaching one millimeter has been built and tested. Furthermore, the results demonstrate that our SBP scheme yields improved performance over traditional Anger techniques for our cMiCE detector. r 2002 Elsevier Science B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Depth of interaction decoding of a continuous crystal detector module.

We present a clustering method to extract the depth of interaction (DOI) information from an 8 mm thick crystal version of our continuous miniature crystal element (cMiCE) small animal PET detector. This clustering method, based on the maximum-likelihood (ML) method, can effectively build look-up tables (LUT) for different DOI regions. Combined with our statistics-based positioning (SBP) method...

متن کامل

Effects of multiple-interaction photon events in a high-resolution PET system that uses 3-D positioning detectors.

PURPOSE The authors' laboratory is developing a dual-panel, breast-dedicated PET system. The detector panels are built from dual-LSO-position-sensitive avalanche photodiode (PSAPD) modules-units holding two 8 x 8 arrays of 1 mm3 LSO crystals, where each array is coupled to a PSAPD. When stacked to form an imaging volume, these modules are capable of recording the 3-D coordinates of individual i...

متن کامل

Investigation of high resolution compact gamma camera module based on a continuous scintillation crystal using a novel charge division readout method

The objective of this study is to investigate a high performance and lower cost compact gamma camera module for a multi-head small animal SPECT system. A compact camera module was developed using a thin Lutetium Oxyorthosilicate (LSO) scintillation crystal slice coupled to a Hamamatsu H8500 position sensitive photomultiplier tube (PSPMT). A two-stage charge division readout board based on a nov...

متن کامل

Resolution Uniformity and Sensitivity of the NIH ATLAS Small Animal PET Scanner: Comparison to Simulated LSO Scanners Without Depth-of-Interaction Capability

Positron emission tomography (PET) scanners designed to image animals the size of rats and mice should possess simultaneously high and uniform spatial resolution and high sensitivity. ATLAS (Advanced Technology Laboratory Animal Scanner), a 6.0 cm diameter effective transverse field-of-view (FOV), 2 cm axial FOV ring-type research scanner seeks these goals by surrounding the animal with eightee...

متن کامل

A Design of a Real Time FPGA - based Three Dimensional Positioning Algorithm

We report on the implementation and hardware platform of a real time Statistics-Based Positioning (SBP) method with depth of interaction processing for a positron emission tomography detector. The processing method works in conjunction with continuous miniature crystal element (cMiCE) detectors using a sensor on the entrance surface design. Our group previously reported on a Field Programmable ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002