Intubation during c-spine immobilization is inherently more difficult because of decreased glottic visualization. The WuScope is a rigid, fiberoptic laryngoscope designed to facilitate visualization and tracheal intubation without neck extension. In a randomized study, these authors compared the WuScope and conventional laryngoscopy with a Macintosh blade in 87 c-spine immobilized patients undergoing elective anesthesia.
منابع مشابه
WuScope versus conventional laryngoscope in cervical spine immobilization.
To the Editor:—We greatly appreciate and commend the recent study by Smith et al. comparing intubation difficulties in cervical spine immobilization with the use of the conventional laryngoscope and the WuScope (Achi Corp., Fremont, CA, and Asahi Optical Co.-Pentax, Tokyo, Japan). As the inventors of this relatively new device, we feel obligated to respond to issues raised by Smith et al. and t...
متن کاملFiberoptic (WuScope) Versus Conventional Lavngoscopy
Background. The WuScope is a rigid, fiberoptic laryngoscope designed to facilitate tracheal intubation without the need for head extension. The study evaluated the WuScope in anesthetized patients with neck immobilization. Methods: Patients were randomized to one of two groups: those receiving fiberoptic laryngoscopy (WuScope, n = 43) and those receiving conventional laryngoscopy (Macintosh bla...
متن کاملA comparison of McCoy, TruView, and Macintosh laryngoscopes for tracheal intubation in patients with immobilized cervical spine
BACKGROUND Cervical spine immobilization results in a poor laryngeal view on direct laryngoscopy leading to difficulty in intubation. This randomized prospective study was designed to compare the laryngeal view and ease of intubation with the Macintosh, McCoy, and TruView laryngoscopes in patients with immobilized cervical spine. MATERIALS AND METHODS 60 adult patients of ASA grade I-II with ...
متن کاملManual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation.
BACKGROUND Manual in-line stabilization (MILS) is recommended during direct laryngoscopy and intubation in patients with known or suspected cervical spine instability. Because MILS impairs glottic visualization, the authors hypothesized that anesthesiologists would apply greater pressure during intubations with MILS than without. METHODS Nine anesthetized and pharmacologically paralyzed patie...
متن کاملAssessment of the storz video Macintosh laryngoscope for use in difficult airways: A human simulator study.
OBJECTIVES Video laryngoscopy has been shown to improve glottic exposure when compared to direct laryngoscopy in operating room studies. However, its utility in the hands of emergency physicians (EPs) remains undefined. A simulated difficult airway was used to determine if intubation by EPs using a video Macintosh system resulted in an improved glottic view, was easier, was faster, or was more ...