The High Peak Current Polarized Electron Source of the Stanford Linear Collider*
نویسنده
چکیده
The Stanford Linear Collider Injector requires two 2 ns pulses of 4.5-5.5 x 1010 electrons, separated by 61 ns at 120 hz, from its source. Since 1992, these currents have been provided by a polarized electron source based on GaAs photocathodes. A beam polarization of 76 + 4% has been measured at the end of the 50 GeV linac. At low photocathode quantum efficiencies, and for excitation near threshold, the maximum current delivered by the source is constrained, not by the space charge limit of the gun, but by a ‘charge limit’ of the photocathode. The charge limited current is proportional to the photocathode quantum efficiency, but the proportionality varies for different photocathode types. Experience with high polarization strained GaAs photocathodes on a test beamline and on the SLC is presented.
منابع مشابه
The Polarized Electron Source of the Stanford Linear Accelerator Center*
The Stanford Linear Accelerator has been running with polarized electrons both in the collider (SLC) mode and in the fixed target mode. The accelerator's polarized electron source is based on a thin, strained GaAs photocathode, which is held at a negative high voltage and illuminated by a Titanium Sapphire laser. The reliability of the source was better than 95% during the eight-month-long 1993...
متن کاملPolarized Electron Sources for Linear Colliders ”
A&TRACT Linear colliders require high peak current beams with low duty factors. Several methods to produce polarized e’ beams-for accelerators have been developed. The SLC, the first linear collider, utilizes a photocathode gun with a GaAs cathode. Although photocathode sources are probably the only er@ical alternative for the next generation of linear colliders, several problems remain to be s...
متن کاملReview of Slc Performance*
The SLAC Linear Collider (SLC) has begun a new era of operation with the SLD detector. During 1991 there was a first engineering run for the SLD in parallel with machine impravements to increase luminosity and reliability. For the 1992 run; a polarized electron source was added and more than 10,OOOZ~with an average of 23% polarization have been logged by the SLD. This paper will discuss the per...
متن کاملPolarized photocathodes make the grade *
Future linear colliders will require high levels of performance from their electron sources. A group at SLAC has recently tested a structure that substantially exceeds current collider polarized electron source pulse-profile requirements. Published in CERN Courier 42 (September 2002), p 19. Work supported by Department of Energy contract DE–AC03–76SF00515.
متن کاملStatus of the Stanford Linear Collider*
The Stanford Linear Collider (SLC) was built to collide single bunches of electrons and positrons head-on at a single interaction point with single beam energies up to 55 GeV. The small beam sizes and high currents required for high luminosity operation have significantly pushed traditional beam quality limits. The Polarized Electron Source produces about 8 x 1010 electrons in each of two bunch...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1993