Spectral Analysis Methods Based on Background Subtraction and Curvature Calculation Used in the Detection or Quantification of Hemolysis and Icterus in Blood-derived Clinical Samples
نویسندگان
چکیده
Objective We aimed to find new methods to detect and quantify hemolysis and icterus which may cause assay biases. These methods need to determine each of these interferents in the presence of various other interferents. They also need to have less stringent requirements in development and implementation than those conventional analyzers currently must satisfy. Design and methods We developed two spectral analysis methods that obtain absorption signals of interest by background subtraction or by calculating the spectral curvatures near the peaks of interest. We optimized and tested the performance of these methods using a plasma sample set with permutations of the levels of hemolysis, icterus, and lipemia (using 510 samples in total). Results The processed signals correlated well with concentrations of hemoglobin and bilirubin, indicators of hemolysis and icterus, respectively. Through iterations of randomly splitting the samples for calibration and testing, the two new methods performed as well as those used on conventional analyzers. We demonstrated that the two methods can lessen the application requirements of 1) prior knowledge of the absorption spectra of individual interferents, 2) calibration over a wide concentration range for each interferent, and 3) the need for full-range spectrophotometers spanning most of the ultraviolet/visible spectrum. We also proposed a hardware setup to detect and quantify hemolysis or icterus with a camera and two optical filters. Conclusions This work indicates that new methods of spectral analysis can reduce practical constraints in the development of interference screening systems. These methods could also benefit other assays that rely on reading spectral signals.
منابع مشابه
A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]
Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...
متن کاملClinical Manifestations of Acute Hemolysis in Children with Glucose-6-Phosphate Dehydrogenase Deficiency in Fars Province, Iran
Background: Absence or deficiency in Glucose-6-phosphate dehydrogenase (G6PD) enzyme in patients with G6PD deficiency presents with a wide spectrum of symptoms. This study evaluates the clinical features of acute hemolysis in children with G6PD deficiency. Materials and Methods: Seventy G6PD deficient children younger than 18 years old were included in this cross sectional study in Dastgheib H...
متن کاملQuantification and Optimization of Candida albicans DNA in Blood Samples Using Real- Time PCR
Background: Candida albicans (C. albicans) is a major cause of candidaemia in people with impaired immunity. Blood culture is a “gold standard” for candidaemia detection but is time-consuming and relatively insensitive. We established a real-time PCR assay for C. albicans detection in blood by LightCycler PCR and melting curve analysis. Methods: Five milliliter blood samples from...
متن کاملComparison of Delta- PCR and Conventional Fragment Analysis for the Detection of FLT3-ITD Mutations in Paired Diagnosis-Relapse Samples of Patients with Acute Myeloid Leukemia
Background & Objective: FLT3-ITD mutation detection has been an integral part of diagnostic work ups focused on acute myeloid leukemia. However, some studies have indicated that the mutation is unstable during the various stages of the disease. The purpose of this study was to evaluate the stability of this marker in paired diagnosis-relapse samples using Delta-PCR method. Materials & Methods:...
متن کاملDetection and discrimination of two Brucella species by multiplex real-time PCR and high-resolution melt analysis curve from human blood and comparison of results using RFLP
Objective(s): Rapid and accurate detection of Brucella abortus and Brucella melitensis from clinical samples is so important because antibiotic treatment has major side effects. This study reveals a new method in detection of clinical samples of brucellosis using real-time PCR and high-resolution melt (HRM) curve analysis. Materials and Methods: 160 brucellosis suspicious samples with more tha...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -
تاریخ انتشار 2017