Gain model for microchannel plates.

نویسنده

  • E H Eberhardt
چکیده

It is shown that microchannel plates (MCPs) tend to act as if they were discrete stage electron multipliers with a fixed number of stages or dynodes if a plausible assumption is made regarding the behavior of the secondary electrons emitted from the semiconducting sidewalls of tubular channel electron multipliers under the grazing incidence conditions predominantly encountered in these multipliers. The shape of the resultant predicted gain-voltage transfer characteristic for the MCP fits well with experimental data, confirming the assumption made and permitting the use of curve matching techniques to determine such important MCP parameters as the average number of active dynodes, the gain per stage, the crossover potential for the MCP wall material, the transit time through the multiplier, etc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nano-engineered ultra high gain microchannel plates

Highly localized and very fast electron amplification of microchannel plates (MCP) enables a large number of high resolution and high sensitivity detection technologies, which provide spatial and/or temporal information for each detected photon/electron/ion/neutron. Although there has been significant progress in photocathode and readout technologies the MCPs themselves have not evolved much fr...

متن کامل

The latest developments of high gain Si microchannel plates

We present our latest results in the development of Silicon micromachined microchannel plates, which open completely new possibilities in the detector technologies. For the first time Z-stacks of Si microchannel plates with pore bias of 5-8 degrees were tested in a high gain photon counting imaging detector without any post-amplification stage with conventional glass MCP's. The gain of Z-stacks...

متن کامل

Photon counting with small pore microchannel plates

We describe the operation of microchannel plates (MCPs) with 3:2mm diameter channels as photon counting detectors of soft X-rays. Gain and temporal resolution measurements are compared with theoretical scaling laws for channel diameter. A minimum pulse width of 264 ps is observed for a two stage multiplier at a total bias voltage of 1930V. r 2006 Elsevier B.V. All rights reserved. PACS: 95.55. ...

متن کامل

Spatial distribution of electron cloud footprints from microchannel plates: Measurements and modeling

The measurements of the electron cloud footprints produced by a stack of microchannel plates ~MCPs! as a function of gain, MCP-to-readout distance and accelerating electric field are presented. To investigate the charge footprint variation, we introduce a ballistic model of the charge cloud propagation based on the energy and angular distribution at the MCP output. We also simulate the Coulomb ...

متن کامل

‘‘Detector walk’’ in position-sensitive detectors with biased microchannel plates

The spatial resolution of high-accuracy microchannel plate ~MCP! detectors has reached the values, where the so-called detector walk ~or image blurring! may start to limit any further improvements. Image blurring with gain is studied in detail for detectors incorporating angular-biased MCPs. It was found that the presence of the pore bias at the output MCP results in a variation of the charge f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 18 9  شماره 

صفحات  -

تاریخ انتشار 1979