The purpose of this study was to measure air-conduction (AC) and bone-conduction (BC) hearing thresholds with pure-tone and filtered sound effect stimuli using standard audiometric equipment. A group of 20 young, normal-hearing listeners participated in the study. Pure-tone stimuli were 250, 500, 1000, 2000, and 4000 Hz. Sound effect stimuli were 12 natural sounds that were spectrally limited to an octave bandwidth centered at either 250, 500, 1000, 2000, or 4000 Hz. The AC and BC detection thresholds were measured using a clinical audiometer (Madsen Orbiter 922) with a B-71 bone oscillator and TDH-50 earphones. Results indicated that detection thresholds for the pure-tone and corresponding octave-band sound effect stimuli were within 3 to 4 dB of each other for both AC and BC testing. The findings support the notion that octave-filtered sound effects are a viable alternative to pure-tone stimuli for use in audiology clinics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection and recognition of octave-band sound effects.

The goal of this study was to determine whether selected sound effects that are spectrally limited to an octave band width could be used as alternative stimuli to pure tones when testing children and other special populations. The uniqueness of octave-band sound effects is that they retain the natural character of everyday sounds while providing frequency-specific information about hearing sens...

متن کامل

تغییرات هدایت استخوانی پس از بازسازی زنجیره استخوانچه‌ای گوش میانی

    Background & Aim: The most common surgically treatable causes of hearing loss are middle ear diseases among which the greatest effect is related to ossicular chain dysfunction. Successful ossicular chain reconstruction certainly improves air conduction thresholds and closes air-bone gap in audiograms, but the effect of this procedure on bone conduction thresholds has remained to be elucidat...

متن کامل

Nonlinear explanation for bone-conducted ultrasonic hearing.

Human listeners can perceive speech from a voice-modulated ultrasonic carrier presented via a bone-conduction stimulator. This study explored the psychoacoustic characteristics and underlying mechanisms of ultrasonic hearing by measuring difference limens for frequency (DLF) for pure tones modulated onto ultrasonic carriers. Human subjects were presented with two pulsed tones and asked to judge...

متن کامل

Does Malleolus non-Lifting Tympanoplasty have any Advantage Over Malleus Lifting Technique?

Introduction: In order to achieve a higher success rate for tympanoplasty, different techniques have been developed, and a wide variety of grafting materials have been developed. One of the techniques currently receiving considerable attention involves not lifting the remaining of eardrum from the malleus and embedding the graft underneath in order to repair the eardrum correctly in its origina...

متن کامل

Comparison of Fluoroplastic Causse Loop Piston and Titanium Soft-Clip in Stapedotomy

Introduction:Different types of prosthesis are available for stapes replacement. Because there has been no published report on the efficacy of the titanium soft-clip vs the fluoroplastic Causse loop Teflon piston, we compared short-term hearing results of both types of prosthesis in patients who underwent stapedotomy due to otosclerosis.Materials and Methods:A total of 57 ears were included in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Academy of Audiology

دوره 10 8  شماره 

صفحات  -

تاریخ انتشار 1999