Modeling the sensitivity to variability relationship in perimetry
نویسندگان
چکیده
PURPOSE Studies in glaucoma patients show that standard automated perimetry results increase in variability as sensitivity decreases. However, the reasons for this change are unclear. This study presents the principle of Divergent Dysfunction as a possible explanation for this change in variability, and incorporates it into a model that can be used to simulate perimetry. METHODS A computer program was written to simulate visual field test results based on the model, using a Full Threshold testing strategy. The validity of the simulation was tested by comparing it with normal sensitivity values, and with test-retest data from 63 participants evaluated five times each over the course of 1 month. The effect on the simulated data of varying parameters of the model was investigated, such as changing the magnitude of variability and the percentages of false positive and negative responses. RESULTS The correlation between subject and simulated test-retest data was 0.987. Several factors were found to affect the sensitivity-variability relationship for the simulated data, most notably the rate of sensitivity decline, the percentage of false positives, and the starting luminance of the test procedure. CONCLUSIONS The principle of Divergent Dysfunction presented here provides a plausible explanation for the sensitivity-variability relationship for standard automated perimetry in glaucomatous eyes. The model and resultant simulation program aim to provide an intuitive demonstration of the principle, which can also be used to examine the effectiveness of different testing strategies. These findings have great implications for future clinical research.
منابع مشابه
Variability components of standard automated perimetry and frequency-doubling technology perimetry.
PURPOSE To evaluate and compare intra- and intertest variability components for both standard automated perimetry (SAP) and frequency-doubling technology (FDT) perimetry in a small group of normal individuals and patients with glaucoma. METHODS The method of constant stimuli (MOCS) was used to examine matched test locations with both SAP and FDT perimetry stimuli in a group of eight normal in...
متن کاملRepeatability of automated perimetry: a comparison between standard automated perimetry with stimulus size III and V, matrix, and motion perimetry.
PURPOSE Standard automated perimetry (SAP) shows a marked increase in variability in damaged areas of the visual field. This study was conducted to test the hypothesis that larger stimuli are associated with more uniform variability, by investigating the retest variability of four perimetry tests: standard automated perimetry size III (SAP III), with the SITA standard strategy; SAP size V (SAP ...
متن کاملOptimizing Contrast Sensitivity Perimetry for Clinical Use
Perimetric testing is used clinically to detect visual field abnormalities and to monitor changes during the course of management. Conventional automated perimetry (CAP), which employs small (0.43 degree) targets (Fig. 1), is hampered by high test-retest variability. Consequently, many tests are required in order to determine whether a patient is stable or progressing. Decreasing test-retest va...
متن کاملPerimetric sensitivity and response variability in glaucoma with single-stimulus automated perimetry and multiple-stimulus perimetry with verbal feedback.
PURPOSE To measure perimetric sensitivity and response variability of glaucomatous patients with single-stimulus automated perimetry (SSAP) and multiple-stimulus perimetry (MSP) with verbal feedback. METHODS Frequency-of-seeing (FOS) data were collected from the same four visual field locations (normal and reduced sensitivity) in one eye of 10 glaucoma patients, using SSAP and MSP. The SSAP t...
متن کاملVariability of the hill of vision and its significance in automated perimetry.
It has been assumed that the retinal threshold sensitivity profile is a standard which decreases predictably with age. On this basis the significance of relative scotomata is decided on certain types of perimeter. The hill of vision was measured in 128 healthy eyes on the Dicon 2000 autoperimeter. We found a large variation between individuals, with no relationship to age. The relevance of the ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 46 شماره
صفحات -
تاریخ انتشار 2006