A comparative study of A1 pulley compliance.

نویسندگان

  • Wen-Lin Tung
  • Chunfeng Zhao
  • Yuichi Yoshii
  • Peter C Amadio
  • Fong-Chin Su
  • Kai-Nan An
چکیده

BACKGROUND Trigger finger is most common in the ring finger, but the reason for this is not known. We hypothesized that the compliance of the A1 pulley might be one of the factors responsible for this phenomenon. The purpose of this study was therefore to compare the compliance of the normal A1 pulley of the thumb, index, middle, ring and little fingers using human cadavers. METHODS Eight normal thumbs, index, middle, ring and little fingers from eight fresh frozen human hand cadavers were used in this experiment. The compliance of the A1 pulley was measured by the resistance when passing a tapered metal rod through the A1 pulley. The slopes of the linear region of radial force/increasing area ratio curve were calculated and analyzed. FINDINGS The mean slope of the linear region of the radial force/increasing area ratio curve was significantly different among the five digits (p<0.05). Post hoc analysis indicated that the mean slope for the middle finger A1 pulleys was larger than the thumb and little finger A1 pulleys (p<0.05). INTERPRETATION The findings did not support our clinical hypothesis that A1 pulley stiffness would parallel the relative frequency of trigger finger by digit.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Length and landmark of A1 pulley in hand: an anatomical study.

OBJECTIVE The purpose of the present study was to identify length and landmark of proximal of A1 pulley in hand. MATERIAL AND METHOD An anatomical study of the length and landmark of A1 pulley in hand was performed in 510 fingers and thumbs from 51 preserved cadavers. There were 25 females and 26 males whose ages at the time of death ranged from 48 to 89 years. RESULTS The lengths of A1 pul...

متن کامل

Percutaneous release of the A1 pulley: a cadaver study.

PURPOSE Percutaneous release of the A1 pulley has been used for treatment of trigger fingers with success. However, lack of direct visualization raises concerns about the completeness of the release and about potential injury to the tendons or neurovascular structures. The purpose of this study was to assess the efficacy and safety of percutaneous release of the A1 pulley in a cadaveric model u...

متن کامل

Quantitative Assessment of First Annular Pulley and Adjacent Tissues Using High-Frequency Ultrasound

Due to a lack of appropriate image resolution, most ultrasound scanners are unable to sensitively discern the pulley tissues. To extensively investigate the properties of the A1 pulley system and the surrounding tissues for assessing trigger finger, a 30 MHz ultrasound system was implemented to perform in vitro experiments using the hypodermis, A1 pulley, and superficial digital flexor tendon (...

متن کامل

Assessment of the Distal Extent of the A1 Pulley Release: A New Technique

OBJECTIVE Sharp division of the A1 pulley is a time-honored technique for the treatment of flexor tendon entrapment; however, this procedure is not without complications. The anatomy of the A1 pulley system has been carefully investigated. Knowledge of superficial anatomic landmarks can assist with demarcating the distal edge of the A1 pulley and prevent damage to the critical A2 pulley. METH...

متن کامل

Hand surface landmarks and measurements in the treatment of trigger thumb.

PURPOSE To determine hand surface landmarks and measurements that may be useful in localizing the A1 pulley and digital neurovascular structures in the treatment of trigger thumb. METHODS We highlighted 4 surface landmarks in 20 adult cadaveric hands: the radial border of the index finger, the ulnar border of the thumb, the thumb interphalangeal joint flexion creases, and the thumb metacarpop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical biomechanics

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2010