Design of a Docking PET and Field-Cycled MRI System for Small Animal Imaging

نویسندگان

  • G. A. Bindseil
  • T. J. Scholl
  • W. B. Handler
  • B. A. Chronik
چکیده

Introduction Efforts to combine anatomical and functional imaging modalities have resulted in the successful development and widespread use of PET/CT systems. PET/MRI would offer substantially better soft tissue contrast, provide high-resolution anatomical information and would be beneficial for longitudinal studies. Combining conventional PET and superconducting MRI faces many technical challenges, especially the incompatibilities between photomultiplier tube-based (PMT) PET detectors and high magnetic fields [1]. Current approaches to PET/MRI typically (a) modify MRI in some manner to make it compatible with conventional PET, or (b) alter PET hardware to make it compatible with conventional MRI. One approach of the second type has been to employ avalanche photodiodes (APD), which are unaffected by magnetic fields, in place of PMTs in an MR-compatible PET insert [2]. An approach of the first type is to use field-cycled (FCMRI) with a conventional PMT-based PET system [3]. Combining PET with FCMRI would enable the use of commercially available, highly optimized PET systems with little physical modification. In this abstract, the authors present their current designs for a docking PET/FCMRI system specifically based on the Siemens Inveon small-animal PET. Methods In FCMRI, a resistive electromagnet generates the main magnetic field and can easily be turned on or off. With the main fields on one can perform normal MR imaging, and, in a small fraction of a second, the main fields can be completely turned off. A fully-functional FCMRI system has been built (Figure 1) [4] and has generated images of good quality (Figure 2). Proof-of-principle tests have shown that linear and mesh PMTs recovered normal operation within several milliseconds of the field being turned off with no long-term effects [3,5]. In addition, the authors have shown that PMT-based PET systems can operate sequentially with an operational FCMRI system (Figure 2). The authors are developing a PET/FCMRI system for small-animal imaging. A Siemens Inveon PET system (Siemens Medical, Knoxville, TN) has been acquired and installed within our labs. The detector consists of a ring of 16 PET modules, each consisting of a row of four LSO crystal blocks (1.59x1.59x10 mm crystals in 20x20 block) coupled to four position-sensitive PMTs. The Inveon system has a large axial FOV (12.7 cm) enabling whole-mouse imaging, and permits fast scanning due to its very high sensitivity (10%). A larger-scale FCMRI system (Figure 3) is under development for docking with the Inveon PET system. At 60-kW-continuous operation, the main magnet produces 0.7 T, and is rough-shimmed to ~250 ppm homogeneity over a 10-cm-diameter sphere. Firstand second-order resistive shims will be used to further reduce the inhomogeneity to better than 10 ppm. The main magnet wire has 7x7 mm cross-section with a 5-mm-diameter liquid cooling channel. With gradients and shims, the bore diameter is 15.9 cm. The length, diameter and mass of the system are 72.5 cm, 61 cm and approx. 900 kg, respectively. The resistance and inductance are 1.85 Ω and 0.81 H. The proposed docking geometry is shown in Figure 4, and the system is best suited for sequential PET/MRI sequences. Tumor uptake of F-FDG in mice is on the order of 45-60 minutes for intraperitoneal injection. Therefore, an efficient sequence could conduct MR for 45 minutes while the mouse metabolizes the radiotracer and then acquire PET data for 15 minutes. The sensitivity of the Inveon system (10%) is substantially greater than that of the PET systems used in current simultaneous approaches to PET/MR (0.23% [2]). Therefore, the proposed system can offer shorter total imaging time or lower radiation dose to the animal for longitudinal studies. A moveable bed with 30 micron precision moves the animal between PET and MR fields of view without disturbing the position of the animal on the bed or disconnecting anaesthetic supply lines. Discussion The proposed PET/FCMRI approach could have several advantages over other PET/MRI approaches. While APD-based PET detectors can achieve timing and energy resolutions comparable to current PMT methods [6], as of this writing, APD-PET is still in development and there are no commercially available systems. The current approach uses the commercially available Inveon system offering state-of-the-art timing & energy resolution, high sensitivity, and highly optimized event processing hardware. While FCMRI is less mature than conventional MRI, it is likely more critical to achieve the best possible PET resolution rather than maximize MR image quality. FCMRI image quality is more than sufficient for the anatomical detail required for image coregistration. Furthermore, FCMRI has several advantages over conventional MRI. One such advantage is the ability to dynamically vary the magnitude of the main field, offering novel T1-dispersion contrast possibilities. Construction of the new FCMRI system and docking with the Siemens Inveon PET system will be completed soon. The final PET/FCMRI system will be relocated to a research hospital environment for performance evaluation and preclinical studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Field Exposure Tests on a Siemens Inveon Small Animal PET System: A Feasibility Study for Multimodality PET and Field-Cyled MRI

Introduction Combining PET with MRI in a hybrid system offers several advantages over PET/CT, namely significantly better soft tissue contrast & resolution and radiation dose reduction for longitudinal studies. Combining conventional PET and superconducting MRI faces many technical challenges, especially the incompatibilities between photomultiplier tube-based (PMT) PET detectors and high magne...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

Fabrication of New 3D Phantom for the measurement of Geometric Distortion in Magnetic Resonance Imaging System

Introduction: Geometric distortion, an important parameter in neurology and oncology. The current study aimed to design and construct a new three-dimensional (3D) phantom using a 3D printer in order to measure geometric distortion and its 3D reproducibility. Material and Methods: In this study, a new phantom ...

متن کامل

First Hybrid Images from a Combined PET and Field-Cycled MRI System

Introduction There is substantial interest in combining functional and anatomical imaging modalities into hybrid systems [1]. Efforts to combine PET and MRI must overcome the incompatibility of conventional PET detectors based on photomultiplier tubes (PMT) with magnetic fields. There are a number of approaches to PET and MRI modify PET detectors to make them compatible with conventional MRI [2...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008