Computer-Assisted Optimization of the Acetabular Rotation in Periacetabular Osteotomy Using Patient's Anatomy-Specific Finite Element Analysis

نویسندگان

  • Sung-Jae Park
  • Sung-Jae Lee
  • Wen-Ming Chen
  • Jung-Hong Park
  • Yong-Soo Cho
  • Taejin Shin
  • Soon-Yong Kwon
چکیده

Periacetabular osteotomy (PAO) is a complex surgical procedure to restore acetabular coverage in the dysplastic hip, and the amount of acetabular rotation during PAO plays a key role. Using computational simulations, this study assessed the optimal direction and amount of the acetabular rotation in three dimensions for a patient undergoing PAO. Anatomy-specific finite element (FE) models of the hip were constructed based on clinical CT images. The calculated acetabular rotation during PAO were 9.7°, 18°, and 4.3° in sagittal, coronal, and transverse planes, respectively. Based on the actual acetabular rotations, twelve postoperative FE models were generated. An optimal position was found by gradually varying the amount of the acetabular rotations in each anatomical plane. The coronal plane was found to be the principal rotational plane, which showed the strongest effects on joint contact pressure compared to other planes. It is suggested that rotation in the coronal plane of the osteotomized acetabulum is one of the primary surgical parameters to achieve the optimal clinical outcome for a given patient.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Does the optimal position of the acetabular fragment should be within the radiological normal range for all developmental dysplasia of the hip? A patient-specific finite element analysis

BACKGROUND The success of Bernese periacetabular osteotomy depends significantly on how extent the acetabular fragment can be corrected to its optimal position. This study was undertaken to investigate whether correcting the acetabular fragment into the so-called radiological "normal" range is the best choice for all developmental dysplasia of the hip with different severities of dysplasia from...

متن کامل

Computer Assisted Planning, Simulation and Navigation of Periacetabular Osteotomy

Periacetabular osteotomy (PAO) is an effective approach for surgical treatment of hip dysplasia in young adults. However, achieving an optimal acetabular reorientation during PAO is the most critical and challenging step. Routinely, the correct positioning of the acetabular fragment largely depends on the surgeons experience and is done under fluoroscopy to provide the surgeon with continuous l...

متن کامل

Stress Analysis of the Human Ligamentous Lumber Spine-From Computer-Assisted Tomography to Finite Element Analysis

Detailed investigation on biomechanics of a complex structure such as the human lumbar spine requires the use of advanced computer-based technique for both the geometrical reconstruction and the stress analysis. In the present study, the computer-assisted tomography (CAT) and finite element method (FEM) are merged to perform detailed three dimensional nonlinear analysis of the human ligamentous...

متن کامل

Theoretical Implications of Periacetabular Osteotomy in Various Dysplastic Acetabular Cartilage Defects as Determined by Finite Element Analysis

BACKGROUND Different extents and locations of acetabular cartilage defect have been supposed to be a major cause of undesirable outcomes of periacetabular osteotomy (PAO) in patients with developmental dysplasia of the hip (DDH). This study aimed to verify whether different locations of cartilage deficiency affect the biomechanical environment in a three-dimensional model utilizing finite eleme...

متن کامل

Evaluation of Constant Thickness Cartilage Models vs. Patient Specific Cartilage Models for an Optimized Computer-Assisted Planning of Periacetabular Osteotomy

Modern computerized planning tools for periacetabular osteotomy (PAO) use either morphology-based or biomechanics-based methods. The latter relies on estimation of peak contact pressures and contact areas using either patient specific or constant thickness cartilage models. We performed a finite element analysis investigating the optimal reorientation of the acetabulum in PAO surgery based on s...