Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3 T using interleaved echo planar imaging.

نویسندگان

  • Himanshu Bhat
  • Qi Yang
  • Sven Zuehlsdorff
  • Kuncheng Li
  • Debiao Li
چکیده

OBJECTIVES The goal of this work was to reduce the scan time of contrast-enhanced whole-heart coronary magnetic resonance angiography (MRA) by using a gradient echo interleaved echo planar imaging (GRE-EPI) sequence at 3 T field strength. MATERIALS AND METHODS A GRE-EPI sequence was optimized to acquire contrast-enhanced whole-heart coronary MRA at 3 T. First-order phase correction was used for alignment of the odd and even echoes in the GRE-EPI echo train. Single and dual reference scan techniques for estimation of the linear phase correction parameters were evaluated using both phantom and volunteer studies. The GRE-EPI readout was combined with parallel imaging for a further reduction in scan time. To avoid image distortions, calibration signals for coil sensitivity estimation were acquired in a separate low resolution GRE scan before the whole-heart GRE-EPI scan. Eight healthy volunteers were scanned with the optimized contrast-enhanced GRE-EPI sequence. GRE-EPI images were acquired during slow infusion (0.3 mL/s) of 0.1 mmol/kg body weight of Gd-BOPTA. For comparison purposes, the same 8 volunteers were scanned again in a separate scan session using a traditional GRE sequence with double the dose (0.2 mmol/kg body weight) of the same contrast agent with the same injection rate. The contrast-enhanced GRE-EPI and contrast-enhanced GRE techniques were compared in terms of relative signal-to-noise ratio (rSNR), relative contrast-to-noise ratio (rCNR), image quality scores, and visualized vessel lengths. RESULTS Both, phantom and volunteer studies demonstrated that the dual reference scan phase correction technique was a key step for obtaining satisfactory image quality using GRE-EPI at 3 T. Whole-heart coronary MRA with a spatial resolution of 1.0 x 1.0 x 2.0 mm3 was acquired with the GRE-EPI sequence in an average scan time of 2.5 +/- 0.6 minutes, compared with 8.6 +/- 2.7 minutes for the GRE technique. The GRE-EPI technique had lower rCNR compared with the GRE sequence. The image quality and coronary artery visualization with the GRE-EPI technique were adequate, and there was no statistically significant difference in the image quality scores, rSNR, and visualized coronary artery lengths between the GRE-EPI and GRE techniques. CONCLUSIONS Contrast-enhanced whole-heart coronary MRA using the GRE-EPI technique resulted in excellent delineation of all the major coronary arteries and compared with current GRE techniques demonstrated a factor of 2 reduction in contrast agent dose and a factor of 3 reduction in scan time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved coverage in dynamic contrast-enhanced cardiac MRI using interleaved gradient-echo EPI.

An interleaved gradient-echo echo-planar imaging (IGEPI) sequence was modified for and applied to dynamic contrast-enhanced imaging of the heart. Using IGEPI, images with 3.0 x 3.9 mm nominal in-plane resolution are acquired in 100 ms, enabling eight slices per heartbeat for a heart rate of 60 beats/min. The acquisition speed and use of saturation prepulses allows acquisition of short- and long...

متن کامل

Automated coronary artery tracking in contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0T

Background Contrast-enhanced whole heart coronary Magnetic Resonance Angiography (MRA) at 3.0 Tesla (T) allows noninvasive detection of obstructive stenoses. Automated vessel segmentation and tracking of centerlines is important for quantitative measurement of stenosis, but remains challenging for coronary MRA. We aimed to develop and validate automated coronary artery segmentation from contras...

متن کامل

Accelerating time-resolved MRA with multiecho acquisition.

A new four-dimensional magnetic resonance angiography (MRA) technique called contrast-enhanced angiography with multiecho and radial k-space is introduced, which accelerates the acquisition using multiecho while maintaining a high spatial resolution and increasing the signal-to-noise ratio (SNR). An acceleration factor of approximately 2 is achieved without parallel imaging or undersampling by ...

متن کامل

Contrast-enhanced whole-heart coronary magnetic resonance angiography at 3.0-T: a comparative study with X-ray angiography in a single center.

OBJECTIVES The purpose of this study was to prospectively evaluate the diagnostic performance of 3.0-T contrast-enhanced whole-heart coronary magnetic resonance angiography (CMRA) in patients with suspected coronary artery disease (CAD). BACKGROUND A slow-infusion, contrast-enhanced whole-heart CMRA approach has recently been developed at 3.0-T. The accuracy of this technique has not yet been...

متن کامل

Assessment of coronary artery disease using 3.0T magnetic resonance coronary angiography: a national multicenter trial

Background 3.0T contrast enhanced whole-heart coronary magnetic resonance angiography (MRA) is a promising method for noninvasive, radiation-free detection and exclusion of obstructive coronary artery disease (CAD); however, the accuracy of this approach has not been determined in a multicenter trial. Methods An ECG-triggered, navigator-gated, inversion-recovery prepared, segmented gradient-ech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 45 8  شماره 

صفحات  -

تاریخ انتشار 2010