A dual sensor flow imaging tomographic system
نویسندگان
چکیده
A dual sensor tomograph for three-component flow imaging has been built at the University of Bergen in cooperation with Christian Michelsen Research AS and Norsk Hydro AS. It utilizes an eight-electrode electrical capacitance tomograph and a γ-ray tomograph with five radiation sources and 85 compact detectors. Embedded transputers using memory-mapped I/O ensure high-speed data acquisition into an Alpha AXP-based on-line processing unit. The first results demonstrate that three-component flow regime identification is possible at rates of about 30 frames per second, provided that sufficient computing capability is available.
منابع مشابه
Electrical capacitance tomography for flow imaging: system model for development of image reconstruc - Circuits, Devices and Systems, IEE Proceedings G
A software tool that facilitates the development of image reconstruction algorithms, and the design of optimal capacitance sensors for a capacitance-based 12-electrode tomographic flow imaging system are described. The core of this software tool is the finite element (FE) model of the sensor, which is implemented in OCCAM-2 language and run on the Inmos T800 transputers. Using the system model,...
متن کاملDesign of sensor electronics for electrical capacitance tomography - Circuits, Devices and Systems, IEE Proceedings G
The design of the sensor electronics for a tomographic imaging system based on electrical capacitance sensors is described. The performance of the sensor electronics is crucial to the performance of the imaging system. The problems associated with such a measurement process are discussed and solutions to these are described. Test results show that the present design has a resolution of 0.3 femt...
متن کاملA Dual colorimetric and Fluorometric Anion Sensor Based on Polymerizable 1, 8-Naphthalimide Dye
A new polymerizable fluorescent sensor based on the photoinduced electron transfer PET for the selective determination of fluoride ions in DMF solutions has been synthesized. The sensing system was prepared by incorporating 4-Amino-1,8-naphthalimide derivatives containing thiourea side chain at the amino moiety AFTN as a neutral F- selective flourophore and was characterized by use of the DSC, ...
متن کاملOptical Doppler tomographic imaging of fluid flow velocity in highly scattering media.
An optical Doppler tomography (ODT) system that permits imaging of fluid flow velocity in highly scattering media is described. ODT combines Doppler velocimetry with the high spatial resolution of low-coherence optical interferometry to measure fluid flow velocity at discrete spatial locations. Tomographic imaging of particle flow velocity within a circular conduit submerged 1 mm below the surf...
متن کاملImage Reconstruction of a Charge Coupled Device Based Optical Tomographic Instrumentation System for Particle Sizing
This research investigates the use of charge coupled device (abbreviated as CCD) linear image sensors in an optical tomographic instrumentation system used for sizing particles. The measurement system, consisting of four CCD linear image sensors are configured around an octagonal shaped flow pipe for a four projections system is explained. The four linear image sensors provide 2,048 pixel imagi...