A Simplified Relationship between Surface Transfer Impedance and Mode Stirred Chamber Shielding Effectiveness of Cables and Connectors

نویسنده

  • Lothar O. Hoeft
چکیده

The relationship between surface transfer impedance and stirred mode chamber shielding effectiveness proposed by Eicher and Boillot has been simplified. This simplified relationship was used to compare the measured stirred mode chamber shielding effectiveness of nine shielding artifacts with the shielding effectiveness of the same samples calculated from transfer impedance measurements made at lower frequencies or obtained by calculation. For samples with colocated apertures, the relationship predicted the mode stirred shielding effectiveness reasonably well. When the apertures were distributed over a finite length, the relationship predicted mode stirred shielding effectiveness’ that were 7 to 10 dB less than those that were measured. This suggests that different relationships must be used for single or colocated apertures and distributed apertures. Above 7 to 10 GHz, the measured stirred mode shielding effectiveness decreases faster than 20 dB/decade. This is probably due to circumferential resonances or resonances within the cable. .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation Between Measured and Simulated Parameters of a Proposed Transfer Standard - Tyco Electronics

Total radiated power of a device can be measured using a mode stirred chamber (MSC). The technique is briefly outlined with emphasis on the peak and average error associated with this technique. A transfer standard, advocated by the IEEE EMCS P482 Working Group, is used as a noise source for a cable radiation study which measured and simulated the total radiated power from a cable-like noise so...

متن کامل

Modeling of Heat Losses Within Combustion Chamber of Diesel Engines

The cylinder working fluid mean temperature, rate of heat fluxes to combustion chamber and temperature distribution on combustion chamber surface will be calculated in this research. By simulating thermodynamic cycle of engine, temperature distribution of combustion chamber will be calculated by the Crank-Nicolson method. An implicit finite difference method was used in this code. Special treat...

متن کامل

بهینه‌سازی عددی یک رادیاتور خانگی و بررسی تجربی ظرفیت حرارتی آن

  Radiators are common devices for heating of home and office spaces and have a close relationship with the energy sector. In a radiator, heat transfer is increased with increasing of air flow rate along heated surface as well as temperature difference between bulk air and heated surface. First, in order to find the optimum design of an Aluminum radiator numerical analysis ...

متن کامل

Shielding Effectiveness of a Lossy Metallic Enclosure

In this paper, shielding effectiveness (SE) of a perforated enclosure with imperfectly conducting walls is evaluated. To this end, first, an accurate numerical technique based on method of Moments (MoM) ispresented. In this method, lossy metallic walls of the enclosure are replaced by equivalent electric surfacecurrent sources. Then, the impedance boundary condition on the imperfectly conductin...

متن کامل

Simulating Crosstalk and EMI in Cables

Cables not only transfer the power needed to run electrical equipment, but also the data signals needed to operate them. To prevent errors and device failures, the same attention must be paid to the choice and installation of the cabling as is paid to the rest of the system. Dealing with data means considering signal integrity (SI). Since data signals are modulated electrical pulses, anything t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004