A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals
نویسندگان
چکیده
This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0 ± 5.9 d) rabbits, rabbits given 10 mg/kg·d(-1) of ribavirin (RIB10, 31.0 ± 4.0 d), and rabbits given 20 mg/kg·d(-1) of ribavirin (RIB20, 25.0 ± 2.9 d) were statistically similar (all p > 0.05) to and linearly correlated (r = 0.96, p < 0.01) with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0 ± 2.7 d; RIB10, 33.0 ± 1.3 d; and RIB20, 27.0 ± 0.8 d). The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models.
منابع مشابه
Pulmonary diffusing capacity: a comparison of breath-holding and steady state methods using carbon monoxide.
Three methods are in current use for measuring the diffusing capacity of the lungs for carbon monoxide (DL). Two of these are steady state methods, and they differ in the methods used to calculate the mean alveolar carbon monoxide tension. Filley, MacIntosh and Wright (1) calculate the alveolar Pco indirectly, assuming the physiological dead space for carbon dioxide to be the same as that for c...
متن کاملClinical assessment of a rebreathing method for measuring pulmonary gas transfer.
A rebreathing method for measuring carbon monoxide transfer factor (TLCO) and transfer coefficient (KCO) is evaluated. The test was performed on 42 subjects. Seventeen of these had normal lung function while the remainder suffered from various conditions, most having fibrosing alveolitis. No patients with severe airways obstruction were included in the group. The results were compared with sing...
متن کاملIs poor glycemic control associated with reduced red blood cell lifespan?
A major assumption in the interpretation of HbA1c as a measure of glycemic control is that the duration of Hb exposure to glucose does not vary among patients who are hematologically normal. In this issue of Diabetes Care, Virtue et al. (1) use an appealingly simple method to quantitate erythrocyte lifespan (2,3) and report an inverse correlation with glycohemoglobin concentration in patients w...
متن کاملRapid CO breath test screening of drugs for protective effects on ribavirin-induced hemolysis in a rabbit model: a pilot study.
Hemolytic anemia is a major side effect of ribavirin antiviral treatment for chronic hepatitis C. Ribavirin dose reduction may compromise the antiviral response and erythropoietin can take several weeks to alleviate anemia. The purpose of the present study was to screen potentially protective drugs against ribavirin-induced hemolytic anemia in a rabbit model, using our modified CO breath test f...
متن کاملReduction of pulmonary capillary blood volume in patients with severe unexplained pulmonary hypertension.
BACKGROUND Unexplained or primary pulmonary hypertension results in an obliteration and obstruction of resistance pulmonary arteries. In these patients gas exchange is impaired and the measurement of gas transfer for carbon monoxide is usually reduced. This has been thought to represent a reduction in pulmonary alveolar capillary blood volume (Vc). A single breath test, measuring simultaneously...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016