Changes of pulmonary vein orifice size and location throughout the cardiac cycle: dynamic analysis using magnetic resonance cine imaging.

نویسندگان

  • Lars Lickfett
  • Timm Dickfeld
  • Ritsushi Kato
  • Harikrishna Tandri
  • Chandrasekhar R Vasamreddy
  • Ronald Berger
  • David Bluemke
  • Berndt Lüderitz
  • Henry Halperin
  • Hugh Calkins
چکیده

INTRODUCTION Anatomically guided left atrial ablation is used increasingly for treatment of atrial fibrillation (AF). Three-dimensional mapping systems used for pulmonary veins (PV) encircling ablation procedures anticipate a stable size and position of the PV orifice. The aim of the current study was therefore to analyze changes of PV orifice size and location throughout the cardiac cycle using cine magnetic resonance imaging (MRI). METHODS AND RESULTS Twenty-five healthy volunteers were studied using a 1.5 Tesla MRI system. MR angiograms were acquired with a breath-hold three-dimensional fast-spoiled gradient-echo imaging (3D FSPGR) sequence in the coronal plane before and after gadolinium injection. Maximum intensity projections and multiplanar reformations were performed to reconstruct images of the PV. Bright blood cine imaging in the axial view was acquired by a steady-state free precession pulse sequence. Twenty bright blood images were obtained per cardiac cycle. The axial (anterior-posterior) PV orifice diameter was measured in all 20 images. For analysis of PV movement the location of the orifice posterior edge was plotted on scale paper. PV orifice size depends on the stage of the cardiac cycle with the largest diameter in late atrial diastole and a mean decrease of 32.5% during atrial systole. Location changes of the PV orifice are in the range of up to 7.2 mm and larger in the coronal (lateral-medial) than in the sagittal (anterior-posterior) direction. CONCLUSION PV orifice size and location is not as stable as anticipated by three-dimensional mapping systems used for PV encircling left atrial ablation procedures. RF application close to the presumed orifice location should therefore be avoided to minimize the risk of PV stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary vein imaging: comparison of 3D magnetic resonance angiography with 2D cine MRI for characterizing anatomy and size.

Pulmonary vein imaging is integral for planning atrial fibrillation ablation procedures. We tested the feasibility of quantifying pulmonary vein ostial diameter using two-dimensional cine cardiac magnetic resonance (2D cine CMR) and three-dimensional magnetic resonance angiography (3D MRA). Nine patients with a history of atrial fibrillation and 20 normal volunteers underwent 2D cine CMR and co...

متن کامل

Bulk motion-independent analyses of water diffusion changes in the brain during the cardiac cycle.

We evaluated dynamic changes in water diffusion in the brain during the cardiac cycle by using cine diffusion MRI. On a 1.5-T MRI, ECG-triggered single-shot diffusion echo planar imaging was used with sensitivity encoding, halfscan, and rectangular field of view techniques for minimizing bulk motion effects such as brain pulsation, with a data-sampling window of 3 ms. The apparent diffusion coe...

متن کامل

Hemodynamic Change in Pulmonary Vein Stenosis after Radiofrequency Ablation: Assessment with Magnetic Resonance Angiography

We present a case of pulmonary vein (PV) stenosis after radio-frequency (RF) ablation, in which a hemodynamic change in the pulmonary artery was similar to that of congenital PV atresia on time-resolved contrast-enhanced magnetic resonance angiography (TR-MRA). A 48-year-old man underwent RF ablation due to atrial fibrillation. The patient subsequently complained of hemoptysis, dyspnea on exert...

متن کامل

Dynamic nature of the aortic regurgitant orifice area during diastole in patients with chronic aortic regurgitation.

BACKGROUND The effective aortic regurgitant orifice area varies with aortic pressure in animal models of acute aortic regurgitation. The purpose of this study was to determine whether the aortic regurgitant orifice area changes during diastole in patients with chronic aortic regurgitation. METHODS AND RESULTS Two-dimensional and Doppler echocardiography were performed immediately before and a...

متن کامل

Influence of longitudinal position on the evolution of steady-state signal in cardiac cine balanced steady-state free precession imaging

Background Emerging quantitative cardiac magnetic resonance imaging (CMRI) techniques use cine balanced steady-state free precession (bSSFP) to measure myocardial signal intensity and probe underlying physiological parameters. This correlation assumes that steady-state is maintained uniformly throughout the heart in space and time. Purpose To determine the effects of longitudinal cardiac moti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular electrophysiology

دوره 16 6  شماره 

صفحات  -

تاریخ انتشار 2005