Diagnostic accuracy of the Matrix 24-2 and original N-30 frequency-doubling technology tests compared with standard automated perimetry.

نویسندگان

  • Lyne Racette
  • Felipe A Medeiros
  • Linda M Zangwill
  • Diana Ng
  • Robert N Weinreb
  • Pamela A Sample
چکیده

PURPOSE To compare the diagnostic accuracy of the Matrix frequency-doubling technology (FDT) 24-2, first-generation FDT N-30 (FDT N-30), and standard automated perimetry (SAP) tests of visual function. METHODS One eye of each of 85 glaucoma patients and 81 healthy controls from the Diagnostic Innovations in Glaucoma Study was included. Evidence of glaucomatous optic neuropathy on stereophotographs was used to classify the eyes. Matrix FDT 24-2, first-generation FDT N-30, and SAP-SITA 24-2 tests were performed on all participants within 3 months. Receiver operating characteristic (ROC) curves were generated and used to determine sensitivity levels at 80% and 90% specificity for mean deviation (MD), pattern standard deviation (PSD), number of total deviation (TD), and pattern deviation (PD) points triggered at less than 5% and 1%. The tests were compared using the best parameter for each test (that with the highest area under the ROC curve) and with the PSD. RESULTS The best parameters were MD for SAP (0.680), PSD for FDT N-30 (0.733), and number of TD less than 5% points for FDT 24-2 (0.774). Using the best parameter, the area under the ROC curve was significantly larger for FDT 24-2 than for SAP (P = 0.01). No statistically significant differences were observed between SAP and FDT N-30 (P = 0.21) and FDT N-30 and FDT 24-2 (P = 0.26). Similar results were obtained when the PSD was used to compare the tests, with the exception that the area under the ROC curve for the FDT N-30 test (0.733) was significantly larger than that of the SAP-SITA (0.641; P = 0.03). CONCLUSIONS The performance of the Matrix FDT 24-2 was similar to that of the first-generation FDT N-30. The Matrix FDT 24-2 test was consistently better than SAP at discriminating between healthy and glaucomatous eyes. Further studies are needed to evaluate the ability of the Matrix FDT 24-2 to monitor glaucoma progression.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of visual field test results obtained through Humphrey matrix frequency doubling technology perimetry versus standard automated perimetry in healthy children

AIMS The aim of this study was to compare the visual field test results in healthy children obtained via the Humphrey matrix 24-2 threshold program and standard automated perimetry (SAP) using the Swedish interactive threshold algorithm (SITA)-Standard 24-2 test. MATERIALS AND METHODS This prospective study included 55 healthy children without ocular or systemic disorders who underwent both S...

متن کامل

Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry.

AIM To determine the number of missed points on frequency doubling technology (FDT) perimetry that optimise the sensitivity and specificity of the test and to determine the topographical accuracy of the test in a clinical setting. METHODS In a prospective study, the perimetric data from 99 patients who underwent both FDT perimetry in the screening mode and Humphrey 24-2 (H24-2) were used to d...

متن کامل

Visual function-specific perimetry for indirect comparison of different ganglion cell populations in glaucoma.

PURPOSE To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous optic neuropathy and ocular hypertension. METHODS One hundred thirty-six eyes from 136 subjects were evaluated with all three tests as well as with standard automated perimetry. ...

متن کامل

Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy.

AIMS To evaluate performance of frequency doubling technology (FDT) perimetry using the Humphrey Matrix 24-2 thresholding program in a hospital eye service (HES) glaucoma clinic. METHODS A random sample of individuals referred consecutively to the HES for suspected glaucoma were examined with 24-2 threshold FDT in addition to routine clinical tests. The discriminatory power of FDT and standar...

متن کامل

EXTENDED REPORT Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy

Aims: To evaluate performance of frequency doubling technology (FDT) perimetry using the Humphrey Matrix 24-2 thresholding program in a hospital eye service (HES) glaucoma clinic. Methods: A random sample of individuals referred consecutively to the HES for suspected glaucoma were examined with 24-2 threshold FDT in addition to routine clinical tests. The discriminatory power of FDT and standar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 49 3  شماره 

صفحات  -

تاریخ انتشار 2008