Validation of the Cozart Amphetamine Microplate EIA for the analysis of amphetamines in oral fluid.
نویسندگان
چکیده
The purpose of this study was to determine the performance characteristics of the Cozart Amphetamine Microplate EIA for detecting amphetamine in oral fluid. Oral fluid samples were collected using the Cozart RapiScan Collection System from 135 volunteer donors from drug treatment clinics. A further 35 oral fluid samples were collected from volunteer donors who were not drug users. The samples were analyzed in the laboratory using the Cozart Amphetamine Microplate EIA and confirmed using gas chromatography-mass spectrometry (GC-MS). The samples were stored frozen until analysis by GC-MS. The intra-assay precision for the Cozart Amphetamine Microplate EIA for amphetamine in oral fluid over forty assays was 2.74-7.1% CV (within assay) and 3.4-7.0% CV (within day). A total of 78 samples were positive for various amphetamines and related designer drugs. The Cozart Amphetamine Microplate EIA, using a cutoff of 45 ng/ml amphetamine equivalents in neat oral fluid, had a sensitivity of 91.7+/-3.3% and a specificity of 95.9+/-1.9% versus GC-MS using a cutoff of 30 ng/ml. A series of potential adulterants of oral fluid were evaluated and shown not to alter the outcome of the test result.
منابع مشابه
Development and validation of the Cozart DDS oral fluid collection device.
The testing of oral fluid for drugs of abuse has increased significantly over recent years and is now commonplace in drug rehabilitation clinics, the workplace, prisons and custody suites. The global problem of identifying drugged drivers has also led to an increase in oral fluid testing at the roadside. The main requirements for the implementation of roadside drug testing are a rapid sample co...
متن کاملSensitivity, specificity, and efficiency in detecting opiates in oral fluid with the Cozart Opiate Microplate EIA and GC-MS following controlled codeine administration.
Oral fluid specimens (N = 1406) were collected from 19 subjects prior to and up to 72 h following controlled administration of oral codeine. Volunteers provided informed consent to participate in this National Institute on Drug Abuse Institutional Review Board-approved protocol. A modification of Cozart Microplate Opiate EIA Oral Fluid Kit (Opiate ELISA), employing codeine calibrators, was used...
متن کاملAnalytical evaluation of four on-site oral fluid drug testing devices.
The use of oral fluid (OF) as an alternative matrix for the detection of drugs of abuse has increased over the last decade, leading to the need for a rapid, simple, and reliable on-site OF testing device. Four on-site OF drug testing devices (Dräger DrugTest 5000, Cozart DDS, Mavand Rapid STAT, and Innovacon OrAlert) were evaluated on 408 volunteers at drug treatment centers. UPLC-MS-MS results...
متن کاملSensitivity and specificity of the Cozart microplate EIA cocaine oral fluid at proposed screening and confirmation cutoffs.
BACKGROUND Oral fluid is currently being evaluated as an alternative matrix for monitoring illicit drugs in federally mandated workplace drug testing, for addiction treatment programs, and for driving under the influence testing. The sensitivity, specificity, and efficiency of the Cozart Microplate EIA Cocaine Oral Fluid Kit (COC ELISA) were determined by comparison with gas chromatography-mass...
متن کاملابعاد آسیب شناختی سوءمصرف آمفتامین
Amphetamines are synthetic stimulants and are taken either legally for medicinal reasons or illegally for recreational use. Amphetamine-type substances are the second most commonly used drugs in the world. Amphetamines being thought to be useful but become diabolic in their reputation as time passes. In this article, physiological and psychological dimension of amphetamine abuse was investigate...