The Anagen system for automated fluorometric immunoassay.

نویسندگان

  • J A Clements
  • G C Forrest
  • R F Jay
  • M Jeffery
  • P M Kemp
  • N J Kjeldsen
  • S J Rattle
  • A Smith
چکیده

We describe a new discrete microprocessor-controlled analyzer, the AN2000, which fully automates fluorometric immunoassays by using a magnetic separation of the solid phase and an alkaline phosphatase label. It can operate in random-access or batch mode with a dwell time typically less than 20 min. The analysis rate is 75 samples per hour and the system can hold refrigerated reagents for as many as 20 different analytes. The substrate and wash buffer are common to all analytes. The system can hold as many as 80 samples at once. The operator can select from the menu-driven operator interface any combination of the available analytes to be run for each sample, using either the touch screen or the keyboard. Results are calculated from a stored calibration curve that is stable for greater than or equal to 1 month. The AN2000 is capable of automating most assay formats because the available timings, volumes, incubations, and wash cycles can be used in any combination.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

New fluorometric enzyme immunoassay for 17beta-estradiol by homogeneous reaction using biotinylated estradiol.

A new fluorometric enzyme immunoassay for 17beta-estradiol (E2) using biotinylated estradiol (BE) as a probe ligand, is described. In this method, E2 is detected indirectly by a solid-phase avidin-biotin binding assay, in which the biotin is immobilized on a microtiter plate (biotin-plate). After the competitive reaction between E2 and BE for the anti-E2 antibody in solution, the free E2 and BE...

متن کامل

A Dual colorimetric and Fluorometric Anion Sensor Based on Polymerizable 1, 8-Naphthalimide Dye

A new polymerizable fluorescent sensor based on the photoinduced electron transfer PET for the selective determination of fluoride ions in DMF solutions has been synthesized. The sensing system was prepared by incorporating 4-Amino-1,8-naphthalimide derivatives containing thiourea side chain at the amino moiety AFTN as a neutral F- selective flourophore and was characterized by use of the DSC, ...

متن کامل

"Stratus" fluorometric enzyme immunoassay system evaluated for determination of free thyroxin.

Exceptfor varying the equilibrationtime, the procedurewas essentiallythatof O’Farrell(4) and Laemmli(5) as modifiedbyTracyet al. (5) and Goldsmithet al (7). Protein3 is the extra protein seen when the equilibrationtime is shortened. Proteins I and 2 are the two additionalproteins kientified by Cloixet al (. ProteinsA andBare markerproteinsalsofoundin Cloix’sgel to identifytheSHR proteins.Molecu...

متن کامل

Cost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems

This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 9  شماره 

صفحات  -

تاریخ انتشار 1992