Direct Potentiometric Method for Human Stress Determination

نویسنده

  • N. Sakač
چکیده

Stress was firstly defined in 19351, as a reaction of humans to external stimuli. In the modern way of life and every day actions, the term stress is very common and has a significant influence on human reactions, health, work ability and mood. There is also a direct connection between stress and depression in humans2. Apart from adults, recent studies show that preschool children are also under stress, and some helping support strategies could reduce it3. Thus, it appears that quantification of stress is a challenging issue, not only in humans, but also in animals4. Stress response is inducing the sympathetic nervous system and hypothalamic-pituitary-adrenal system, where hormone regulation is included (norepinephrine and cortisol). Invasive techniques measure hormone levels in the blood as an indicator of stress, but these levels are very low and hard to measure, and response time is too long and delayed by 20–30 minutes in response to loading stress. The use of salivary biomarkers has gained increased popularity over the past decade in psychological and biomedical research. While the measurement of free cortisol in saliva has proven to be in correlation with stress5, salivary amylase activity has appeared as a new highlight in stress measurement6. When secretion of the salivary amylase is stimulated by direct innervations, its response is very quick, generally within one to a few minutes, a markedly quicker response than that induced by hormonal regulation7,8. Salivary glands amplify the low levels of norepinephrine and give a faster and more sensitive response to the psychological stress than cortisol. To date, there are no international standard measurement methods for human salivary amylase activity. Salivary amylase has a high activity, ranging from several thousands to hundred thousand units per litre9. According to literature, in human and animal science, amylase activity rises remarkably under autonomic system activation10, such as response to a) physical stressors like exercise11,12, exposure to a high-pressure chamber13, running14, bicycle exercise15, sky diving or cold exposure16; and b) psychological stress7 or relaxation interventions17. While it seems clear that alpha-amylase levels rise following physical stress, the response to psychological stressors appears to be more inconsistent. This might be due to the psychological nature of the stressors employed or other methodological details5. Furthermore, concerning medical aspects, salivary amylase activity has also been employed as a marker for schizophrenia, since several researches indicate that the autonomic nervous system dysfunctions in patients with schizophrenia18; in patients with chronic relapsing pancreatitis, the activity of the salivary amylase was significantly lowered19 and recently, there have been attempts to suggest salivary amyDirect Potentiometric Method for Human Stress Determination

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Sensitive and Selective Liquid Membrane Electrode for Direct Determination of Trace Amounts of Chromium

N-(2H-[1,2,4]thiadiazolo[2,3-a]pyridine-2-ylidene)benzamide was used as a selective sensing material in the PVC membrane to construction of a new chromium ion selective electrode. This liquid membrane electrode worked well with a Nernstian response of 19.7 ±0.4 mV decade-1 of Cr(III) in a wide dynamic concentration range of 8.0× 10-6-1.0×10-1 M. The electrode had relatively short response time ...

متن کامل

Ion-Selective Carbon Paste Electrode Based on 2-Amino-N-benzthioazolyl Benzamide (ABTB) for Determination of Copper (II) by Potentiometric Method

2-Amino-N-benzthioazolyl benzamide (ABTB) was synthesized, characterized and used for thefabrication of a potentiometric sensor for Cu2+ metal ions. The electrode exhibits linear response to Cu(II) over a wide concentration range (4.79×10 -8 – 1.85×10 -1 M) with Nernstian slope of 30 ± 1.5 mVper decade. The electrode can be used in the pH range from 2 to 9. It has a fast response time of about1...

متن کامل

Potentiometric Method to Determine Montelukast Sodium in its Tablets with In-line Monitoring of its Dissolution Behaviour

Direct drug determination without any pervious treatment steps is the most environmentally friendly method of analysis. Traditional analysis methods usually involve a pre-treatment step before analysis and this consumes time and organic solvents. This work describes direct potentiometric method by using ion selective electrode to determine Montelukast Sodium in its pure drug substance and in ta...

متن کامل

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015