Biomechanical Analysis of a Novel Prosthesis Based on the Physiological Curvature of Endplate for Cervical Disc Replacement

نویسندگان

  • Cheng-Cheng Yu
  • Ding-Jun Hao
  • Da-Geng Huang
  • Li-Xiong Qian
  • Hang Feng
  • Hou-Kun Li
  • Song-Chuan Zhao
چکیده

STUDY DESIGN Biomechanical analysis of a novel prosthesis based on the physiological curvature of endplate was performed. OBJECTIVE To compare the biomechanical differences between a novel prosthesis based on the physiological curvature of the endplate and the Prestige LP prosthesis after cervical disc replacement (CDR). SUMMARY OF BACKGROUND DATA Artificial disc prostheses have been widely used to preserve the physiological function of treated and adjacent motion segments in CDR, while most of those present a flat surface instead of an arcuate surface which approximately similar to anatomic structures in vivo. We first reported a well-designed artificial disc prosthesis based on the physiological curvature of the endplate. METHODS Three motion segments of 24 ovine cervical spines (C2-5) were evaluated in a robotic spine system with axial compressive loads of 50N. Testing conditions were as follows: 1) intact, 2) C3-4 CDR with artificial disc prosthesis based on the physiological curvature of the endplate, and 3) C3-4 CDR with the Prestige LP prosthesis. The range of motion (ROM) and the pressures on the inferior surface of the two prostheses were recorded and analyzed. RESULTS As compared to the intact state, the ROM of all three segments had no significant difference in the replacement group. Additionally, there was no significant difference in ROM between the two prostheses. The mean pressure on the novel prosthesis was significantly less than the Prestige LP prosthesis. CONCLUSION ROM in 3 groups (intact group, CDR group with novel prosthesis and CDR group with Prestige LP) showed no significant difference. The mean pressure on the inferior surface of the novel prosthesis was significantly lower than the Prestige LP prosthesis. Therefore, the novel artificial disc prosthesis is feasible and effective, and can reduce the implant-bone interface pressure on the endplate, which may be one possible reason of prosthesis subsidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical evaluation of cervical disc replacement with a novel prosthesis based on the physiological curvature of endplate

BACKGROUND Most of the current available cervical disc prostheses present a flat surface instead of an arcuate surface which is most similar to the morphology of cervical endplate. Therefore, we designed a novel prosthesis (Pretic-I, Trauson) based on the physiological curvature of the cervical endplate. Biomechanical evaluation of cervical disc replacement (CDR) with this novel prosthesis was ...

متن کامل

A morphometric study of the middle and lower cervical vertebral endplates and their components

Cervical disc arthroplasty is a common method of treating cervical degenerative disease. However, the footprints of most prosthesis dimensions are obtained from data of Caucasian individuals. Besides, there is a large discrepancy between footprints of currently available cervical disc prostheses and anatomic dimensions of cervical endplates. We aimed to detail the three-dimensional (3D) anatomi...

متن کامل

Cervical total disc replacement, part two: clinical results.

This article focuses on the clinical results of three prostheses (the Bryan Cervical Disc, the Bristol Disc, and the ProDisc-C) for cervical total disc replacement. Background on the development, design, and biomechanical characteristics of each prosthesis is given and surgical indications and clinical results are summarized and analyzed.

متن کامل

In vitro biomechanical comparison after fixed- and mobile-core artificial cervical disc replacement versus fusion

In vitro biomechanical analysis after cervical disc replacement (CDR) with a novel artificial disc prosthesis (mobile core) was conducted and compared with the intact model, simulated fusion, and CDR with a fixed-core prosthesis. The purpose of this experimental study was to analyze the biomechanical changes after CDR with a novel prosthesis and the differences between fixed- and mobile-core pr...

متن کامل

In vitro-analysis of kinematics and intradiscal pressures in cervical arthroplasty versus fusion – A biomechanical study in a sheep model with two semi-constrained prosthesis

BACKGROUND As an alternative technique to arthrodesis of the cervical spine, total disc replacement (TDR) has increasingly been used with the aim of restoration of the physiological function of the treated and adjacent motions segments. The purpose of this experimental study was to analyze the kinematics of the target level as well as of the adjacent segments, and to measure the pressures in th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016