Clinical evaluation of scanning laser polarimetry: I. Intraoperator reproducibility and design of a blood vessel removal algorithm.
نویسندگان
چکیده
AIMS To evaluate the reproducibility of the retardation values (change in polarisation) obtained with the scanning-laser polarimeter in a series of normal subjects and glaucoma patients. To improve the analysis of the raw data by devising and evaluating a blood vessel removal algorithm. METHODS Scanning laser polarimetry was performed on 10 normal subjects and 10 glaucoma patients. A series of six images was obtained from each eye. The normal subjects were re-imaged 3 months after their initial assessment. The retardation values obtained from each eye were analysed using the authors' own methods, including the use of an algorithm to remove blood vessels from the polar profiles. The reproducibility of these measurements and the performance of the blood vessel removal algorithm were assessed. RESULTS The "individual point" coefficient of variation was approximately 12.5% for normal subjects and 17.0% for glaucoma patients. The "integral" coefficient of variation for these groups was approximately 5.5% and 9.5% respectively. The reproducibility of the measurements did not improve with an increased number of measurements. There was no difference in the reproducibility of the measurements in normal subjects over time. The blood vessel removal algorithm improved the reproducibility of the measurements when the shape of the profile was assessed. CONCLUSION The intraoperator reproducibility of retardation values obtained with the scanning laser polarimeter is satisfactory for its use as a clinical tool. The use of a blood vessel removal algorithm improves the reproducibility of the measurements and also assists the clinician in the interpretation of the polar profiles. Furthermore, it allows the construction of normal database polar profiles, thereby enabling the identification, location and quantification of retinal nerve fibre layer damage in an "at risk" individual's polar profile.
منابع مشابه
Clinical evaluation of scanning laser polarimetry: II. Polar profile shape analysis.
AIMS To devise a method to describe and quantify the shape of polar profiles obtained with the scanning laser polarimeter and to compare this measurement with other polar profile measurements in a series of normal subjects and glaucoma patients. METHODS Scanning laser polarimetry was performed on 54 normal subjects and 74 glaucoma patients. The retardation values obtained from one randomly ch...
متن کاملScanning laser polarimetry of the retinal nerve fibre layer in primary open angle and capsular glaucoma.
AIMS To evaluate the clinical value of scanning laser polarimetry with the nerve fibre analyser type II in primary open angle glaucoma (POAG) and capsular glaucoma. METHODS Scanning laser polarimetry was performed on one eye of 30 patients suffering from POAG, 25 patients suffering from capsular glaucoma, and on 35 healthy control subjects. The retinal nerve fibre layer (RNFL) thickness value...
متن کاملPhase retardation measurement of retinal nerve fiber layer by polarization-sensitive spectral-domain optical coherence tomography and scanning laser polarimetry.
Phase retardation of in vivo human retinal nerve fiber layer (RNFL) is quantitatively measured by two methods--polarization-sensitive spectral-domain optical coherence tomography (PS-SD-OCT) and scanning laser polarimetry (SLP). An en face cumulative phase retardation map is calculated from the three-dimensional (3-D) phase retardation volume of healthy and glaucomatous eyes measured by PS-SD-O...
متن کاملCorrelation of Retinal Vessel Analysis and Nerve Fiber Layer Thickness in Normal Tension Glaucoma
Background: To investigate the retinal vessel diameter and its possible relationship with the retinal nerve fiber layer (RNFL) thickness in normal tension glaucoma (NTG). Methods: 86 NTG patients with detailed eye examination including retinal vessel analysis (DVA) and measurement of the RNFL thickness with scanning laser polarimetry (SLP; GDxVCC) were included in this retrospective study. The ...
متن کاملCumulative Clinical Evaluation of Transcutaneous Blood Laser Irradiation on Hemodynamic Changes in Anesthesia of Dogs
Objectives-The aims of this study were evaluation the effects of blood laser irradiation on hemodynamic parameters, the amount of anesthetic drugs in maintenance of anesthesia and duration of recovery. Animals- Fifteen mixed breed dogs Procedures- dogs (25.0 ± 3.6 kg) were divided into three groups (n=5). The group I was acted as control and received only cold laser. The group II was premedicat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The British journal of ophthalmology
دوره 82 3 شماره
صفحات -
تاریخ انتشار 1998