Evaluation of dosimetric misrepresentations from 3D conventional planning of liver SBRT using 4D deformable dose integration

نویسندگان

  • Unjin A. Yeo
  • Michael L. Taylor
  • Jeremy R. Supple
  • Shankar Siva
  • Tomas Kron
  • Daniel Pham
  • Rick D. Franich
چکیده

The purpose of this study is to evaluate dosimetric errors in 3D conventional plan- ning of stereotactic body radiotherapy (SBRT) by using a 4D deformable image registration (DIR)-based dose-warping and integration technique. Respiratory- correlated 4D CT image sets with 10 phases were acquired for four consecutive patients with five liver tumors. Average intensity projection (AIP) images were used to generate 3D conventional plans of SBRT. Quasi-4D path-integrated dose accumulation was performed over all 10 phases using dose-warping techniques based on DIR. This result was compared to the conventional plan in order to evalu- ate the appropriateness of 3D (static) dose calculations. In addition, we consider whether organ dose metrics derived from contours defined on the average intensity projection (AIP), or on a reference phase, provide the better approximation of the 4D values. The impact of using fewer (< 10) phases was also explored. The AIP- based 3D planning approach overestimated doses to targets by 1.4% to 8.7% (mean 4.2%) and underestimated dose to normal liver by up to 8% (mean -5.5%; range -2.3% to -8.0%), compared to the 4D methodology. The homogeneity of the dose distribution was overestimated when using conventional 3D calculations by up to 24%. OAR doses estimated by 3D planning were, on average, within 10% of the 4D calculations; however, differences of up to 100% were observed. Four-dimensional dose calculation using 3 phases gave a reasonable approximation of that calculated from the full 10 phases for all patients, which is potentially useful from a workload perspective. 4D evaluation showed that conventional 3D planning on an AIP can significantly overestimate target dose (ITV and GTV+5mm), underestimate normal liver dose, and overestimate dose homogeneity. Implementing nonadaptive quasi- 4D dose calculation can highlight the potential limitation of 3D conventional SBRT planning and the resultant misrepresentations of dose in some regions affected by motion and deformation. Where the 4D approach is unavailable, contouring on the full expiration phase may yield more accurate dose calculations, most relevant in the case of the healthy liver, but the absolute dose differences are in general small for the other healthy organs. The technique has the potential to quantify under- and over-dosage and improve treatment plan evaluation, retrospective plan analysis, and clinical outcome correlation. 

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy

BACKGROUND The purpose of this study was to assess the impact on dose to the planning target volume (PTV) and organs at risk (OAR) by using four differently generated CT datasets for dose calculation in stereotactic body radiotherapy (SBRT) of lung and liver tumors. Additionally, dose differences between 3D conformal radiotherapy and volumetric modulated arc therapy (VMAT) plans calculated on t...

متن کامل

Analysis of 3d and 4d Proton Treatment Planning for Hepatic Tumors

The purpose of this study is to assess the difference between 4D liver dose calculations versus standard 3D treatment planning and to investigate the dosimetric gain of gating on radiation dose to normal tissue. 4DCT scans are collected for 25 patients with hepatic tumors treated by proton radiotherapy. The 4D treatment planning process explicitly takes into account respiratory motion of abdomi...

متن کامل

Impact of temporal probability in 4D dose calculation for lung tumors

The purpose of this study was to evaluate the dosimetric uncertainty in 4D dose calculation using three temporal probability distributions: uniform distribution, sinusoidal distribution, and patient-specific distribution derived from the patient respiratory trace. Temporal probability, defined as the fraction of time a patient spends in each respiratory amplitude, was evaluated in nine lung can...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

A deliverable four-dimensional intensity-modulated radiation therapy-planning method for dynamic multileaf collimator tumor tracking delivery.

PURPOSE To develop a deliverable four-dimensional (4D) intensity-modulated radiation therapy (IMRT) planning method for dynamic multileaf collimator (MLC) tumor tracking delivery. METHODS AND MATERIALS The deliverable 4D IMRT planning method involves aligning MLC leaf motion parallel to the major axis of target motion and translating MLC leaf positions by the difference in the target centroid...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014