Alteration in irrigant flow and deflection of flexible ureteroscopes with nitinol baskets.

نویسندگان

  • Caroline D Ames
  • Juan M Perrone
  • Kyle J Weld
  • Kelley V Foyil
  • Yan Yan
  • Ramakrishna Venkatesh
  • Jaime Landman
چکیده

BACKGROUND AND PURPOSE Introduction of an instrument into the working channel of ureteroscopes adversely affects flow and deflection. We evaluated the alterations in ureteroscope channel flow and deflection caused by available Nitinol(R) baskets. MATERIALS AND METHODS We compared the effects of 11 Nitinol baskets on irrigation flow and deflection of three flexible ureteroscopes (Olympus P3, ACMI DUR8, and ACMI DUR8 Elite). ANOVA was used to compare the loss of flow and deflection for each basket, with P values adjusted for multiple comparisons by the Tukey method. RESULTS Ureteroscope flow and deflection were progressively adversely affected by all baskets as their diameter increased. The average baseline irrigant flow (46.6 mL/min) was decreased significantly: by 78.5% (to 9.9 mL/min), with the smaller baskets (Microvasive 1.9F and Cook 2.2F) and by 99.1% (to 0.4 mL/min) with the larger baskets (ACMI 3.0F and Microvasive 3.0F). Similarly, the mean baseline upward deflection (162 degrees) decreased by 2 degrees (1.2%) for the Cook 2.4F N-Compass and by 20 degrees (12.3%) for the ACMI 3.0F. Loss of downward deflection from baseline (170 degrees) ranged from 6 degrees (3.5%) for the Microvasive 1.9F to 17 degrees (10%) for the Microvasive 2.6F grasping forceps. The least deterioration in flow and deflection occurred with the two smallest baskets (Microvasive 1.9F and Cook 2.2F). CONCLUSION Ureteroscope irrigation flow and deflection deteriorate progressively with larger-caliber Nitinol baskets. The Microvasive 1.9F and Cook 2.2F baskets resulted in the least deterioration of irrigation and deflection metrics. However, basket size is not the only factor responsible for changes in flow and ureteroscope deflection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the mechanical, flow, and optical properties of contemporary flexible ureteroscopes.

OBJECTIVES New designs have improved the ability of flexible ureteroscopes to assess the upper urinary tract. However, limitations of tip deflection may interfere with diagnosis and treatment of lower pole renal pathologic features and smaller working channels may impair irrigant flow. Our purpose was to compare the new flexible ureteroscopes with prior models to determine whether engineering a...

متن کامل

Comparison of New Single-Use Digital Flexible Ureteroscope Versus Nondisposable Fiber Optic and Digital Ureteroscope in a Cadaveric Model

PURPOSE To evaluate LithoVue, the new single-use digital flexible ureteroscope, in a human cadaveric model and compare it with a nondisposable fiber optic and digital flexible ureteroscopes. MATERIALS AND METHODS LithoVue, a conventional fiber optic, and digital flexible ureteroscopes were each tested in four renal units of recently deceased female cadavers by three surgeons. The following pa...

متن کامل

Impressive Performance: New Disposable Digital Ureteroscope Allows for Extreme Lower Pole Access and Use of 365 μm Holmium Laser Fiber

BACKGROUND Since the development of the first flexible ureteroscope, in 1964, technological advances in image quality, flexibility, and deflection have led to the development of the first single-use digital flexible ureteroscope, LithoVue™ (Boston Scientific, Marlborough, MA). With respect to reusable fiber-optic and now digital ureteroscopes, there is an initial capital cost of several thousan...

متن کامل

Comparison of Peditrol irrigation device and common methods of irrigation.

BACKGROUND AND PURPOSE The Peditrol is a novel hands-free irrigation device that delivers a bolus of irrigant through the ureteroscope when the foot pedal is deployed. The purpose of this study was to compare the flow and pressures created by the Peditrol with those of commonly used methods of irrigation. MATERIALS AND METHODS Flows through a flexible 6.9F Olympus ureteroscope (F-URS) and a 7...

متن کامل

Correlation between Deflection and Unevenness Index for Evaluation of Flexible Pavements

Evaluating existing flexible pavement condition is a pre-requisite to choose improvement technique that has to be adopted to enhance its quality. To evaluate existing pavements, non-destructive testing methods are desirable. Benkelman Beam and 5th Wheel Bump Integrator are used to conduct non-destructive tests like deflection and roughness surveys on the existing pavement of 4 lane divided carr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of endourology

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2006