The Exploration of Peptide Biomarkers in Malignant Pleural Effusion of Lung Cancer Using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

نویسندگان

  • Jing Xu
  • Bin Xu
  • Chuanhao Tang
  • Xiaoyan Li
  • Haifeng Qin
  • Weixia Wang
  • Hong Wang
  • Zhongyuan Wang
  • Liangliang Li
  • Zhihua Li
  • Hongjun Gao
  • Kun He
  • Xiaoqing Liu
چکیده

Background. Diagnoses of malignant pleural effusion (MPE) are a crucial problem in clinics. In our study, we compared the peptide profiles of MPE and tuberculosis pleural effusion (TPE) to investigate the value of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) in diagnosis of MPE. Material and Methods. The 46 MPE and 32 TPE were randomly assigned to training set and validation set. Peptides were isolated by weak cation exchange magnetic beads and peaks in the m/z range of 800-10000 Da were analyzed. Comparing the peptide profile between 30 MPE and 22 TPE samples in training set by ClinProTools software, we screened the specific biomarkers and established a MALDI-TOF-MS classification of MPE. Finally, the other 16 MPE and 10 TPE were included to verify the model. We additionally determined carcinoembryonic antigen (CEA) in MPE and TPE samples using electrochemiluminescent immunoassay method. Results. Five peptide peaks (917.37 Da, 4469.39 Da, 1466.5 Da, 4585.21 Da, and 3216.87 Da) were selected to separate MPE and TPE by MALDI-TOF-MS. The sensitivity, specificity, and accuracy of the classification were 93.75%, 100%, and 96.15%, respectively, after blinded test. The sensitivity of CEA was significantly lower than MALDI-TOF-MS classification (P = 0.035). Conclusions. The results indicate MALDI-TOF-MS is a potential method for diagnosing MPE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of 10 Candidate Biomarkers Distinguishing Tuberculous and Malignant Pleural Fluid by Proteomic Methods

PURPOSE Pleural effusion, an accumulation of fluid in the pleural space, usually occurs in patients when the rate of fluid formation exceeds the rate of fluid removal. The differential diagnosis of tuberculous pleurisy and malignant pleural effusion is a difficult task in high tuberculous prevalence areas. The aim of the present study was to identify novel biomarkers for the diagnosis of pleura...

متن کامل

Proteomic pilot study of tuberculosis pleural effusion.

To discuss the differences in protein expression among tuberculosis pleural effusion (TBPE), malignant pleural effusion (MPE) and transudative pleural effusion (TSPE). We recruited 50 patients with pleural effusion, including 20 TBPEs, 17 MPEs and 13 TSPEs. Using the two-dimensional electrophoresis (2-DE) and matrix-assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TO...

متن کامل

Rapid screening of protein profiles of human breast cancer cell lines using non-porous reversed-phase high performance liquid chromatography separation with matrix-assisted laser desorption/ionization time-of-flight mass spectral analysis.

Non-porous reversed-phase (NP-RP) HPLC has been used to rapidly generate protein profiles of whole cell lysates of human breast cancer cell lines. The non-porous packing material used was silica coated with C18, which provided rapid separation with high collection efficiency of proteins from cell lysates. This method was used to study the differences in protein profiles among normal cells and f...

متن کامل

Detection and significance of small-cell lung cancer serum protein markers using MALDI-TOF-MS

Early diagnosis is vital to improving the survival rate of patients with small-cell lung cancer (SCLC). Considering recent applications of mass spectrometry (MS) to cancer research, this study aimed to identify reliable biomarkers for an early and accurate diagnosis of SCLC. A total of 160 serum samples, including 80 from SCLC patients and 80 from healthy controls, were analysed using the ClinP...

متن کامل

Use of anchorchip-time-of-flight spectrometry technology to screen tumor biomarker proteins in serum for small cell lung cancer

BACKGROUND The purpose of this study is to discover potential biomarkers in serum for the detection of small cell lung cancer (SCLC). METHODS 74 serum samples including 30 from SCLC patients and 44 from healthy controls were analyzed using ClinProt system combined with matrix-assisted laser desorption/ionization time-of-flight masss spectrometry (MALDI-TOF-MS). ClinProt software and genetic a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017