Sensitive chemiluminescence immunoassay for E. coli O157:H7 detection with signal dual-amplification using glucose oxidase and laccase.

نویسندگان

  • Yun Zhang
  • Chen Tan
  • Ruihua Fei
  • Xiaoxiao Liu
  • Yuan Zhou
  • Jing Chen
  • Huanchun Chen
  • Rui Zhou
  • Yonggang Hu
چکیده

A novel, sensitive chemiluminescence (CL) immunoassay for Escherichia coli O157:H7 detection with signal dual-amplification using glucose oxidase (GOx) and laccase was investigated. The method was based on the characterization of a luminol-H2O2-laccase reaction. Compared with the horseradish peroxidase-based biosensor, laccase exhibited high catalytic activity in strong alkaline medium, which was compatible with the luminol system. The capture antibody was immobilized onto the magnetic bead (MB) surfaces. The detection antibody was linked with GOx through biotin-avidin recognition. Accordingly, the bioconjugation of MB-caputure antibody- E. coli O157:H7-detection antibody-GOx catalyzed the substrate glucose, thereby generating H2O2. E. coli O157:H7 was then detected by measuring the CL intensity after H2O2 formation. Under optimal conditions, the calibration plot obtained for E. coli O157:H7 was approximately linear from 4.3 × 10(3) colony-forming unit (CFU) mL(-1) to 4.3 × 10(5) CFU mL(-1), and the total assay time was <2.0 h without any enrichment. The limit of detection for the assay was 1.2 × 10(3) CFU mL(-1) (3σ), which was considerably lower than that of enzyme-linked immunosorbent assay method (1.0 × 10(5) CFU mL(-1)) (3σ). A series of repeatability measurements of using 1.7 × 10(4) CFU mL(-1) E. coli O157:H7 exhibited reproducible results with a relative standard deviation (RSD) of 3.5% (n = 11). Moreover, the proposed method was successfully used to detect E. coli O157:H7 in synthetic samples (spring water, apple juice, and skim milk), which indicated its potential practical application. This protocol can be applied in various fields of study.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Enzyme-linked immunomagnetic chemiluminescent detection of Escherichia coli O157:H7.

E. coli O157:H7 is a pathogenic microorganism that has been implicated in numerous cases of foodborne illnesses. A variety of rapid methods exist that show promise for the presumptive detection of this pathogen without the immediate need for incubating test samples for hours to days in microbial enrichment and culture media. In recent years, highly sensitive chemiluminescence has become a more ...

متن کامل

Rapid and ultrasensitive E. coli O157:H7 quantitation by combination of ligandmagnetic nanoparticles enrichment with fluorescent nanoparticles based two-color flow cytometry.

A novel, fast and sensitive determination strategy for E. coli O157:H7 has been developed by combination of ligandmagnetic nanoparticles (LMNPs) enrichment with a fluorescent silica nanoparticles (FSiNPs) based two-color flow cytometry assay (LMNPs@FSiNPs-FCM). E. coli O157:H7 was first captured and enriched through the lectin concanavalin A (Con A) favored strong adhesion of E. coli O157:H7 to...

متن کامل

Comparison of enzyme-linked immunomagnetic chemiluminescence with U.S. Food and Drug Administration's Bacteriological Analytical Manual method for the detection of Escherichia coli O157:H7.

Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, e...

متن کامل

PCR detection of Escherichia coli O157:H7 directed from slaughtered cattle in Shiraz, Iran

  Escheric hia coli O157:H7 lives in the intestines of healthy cattle, and can contaminate meat during slaughtering pr actices . Detection of the low infectious dosage of bacterium requires a sensitive method. We developed polymerase chain reaction (PCR) assays to detect the gene Stx2 irrespective of the bacterial serotype. In this study, the detection limit of the PCR protocol in detecting Stx...

متن کامل

Dipstick immunoassay to detect enterohemorrhagic Escherichia coli O157:H7 in retail ground beef.

A sensitive and easy-to-perform dipstick immunoassay to detect Escherichia coli O157:H7 in retail ground beef was developed by using a sandwich-type assay (with a polyclonal antibody to E. coli O157 as the capture antibody and a monoclonal antibody to E. coli O157:H7 as the detection antibody) on a hydrophobic polyvinylidine difluoride-based membrane. E. coli O157:H7 in ground beef could be det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 86 2  شماره 

صفحات  -

تاریخ انتشار 2014