Management of tibial bone defects due to high energy trauma using the locally manufactured external fixator by segmental bone transport.
نویسندگان
چکیده
BACKGROUND Bone defect in long bones is a problem in orthopaedic which needs proper treatment to restore limb length and function of the limb. There are various treatment modalities available to fill the detect like bone grafting, vascularised bone graft, allograft and bone transport through fixators (Ring or Uniplanner). This study was done to determine the outcome of locally manufactured External Fixator (Naseer and Awais ) in the management of tibial bone defect due to trauma. METHODS This descriptive study was conducted on 20 patients in orthopedic department in Lady Reading Hospital Peshawar and Ayub Teaching Hospital Abbottabad, from Nov 1997 to Nov 2002. Patients from either gender aged between 20 to 50 years, having tibial bone defect of more than five centimeter due to trauma were included in the study. Follow up was done for two years. Outcome measures were adopted according to the classification of the Association for the Study and Application of the Method of llizarov (ASAMI) based on clinical (functional) and radiological findings (defect filling). RESULTS Out of 20 patients 14 (70%) were males and 6 (30%) were female patients. Right tibia was involved in 12 patients (60%) and left tibia in 8 patients (40%). Bony defects due to firearm injury were in 14 patients (70%) and road traffic accidents were in 6 patients (30%). Radiological (bony) results were excellent in 12 patients (60%), good in 2 patients (10%), fair in 3 patients (15%) and poor in 3 patients (15%). Clinical (functional) results were excellent in 7 patients (35%), good in 8 patients (40%), fair in 4 patients (20%,) and poor in 1 patients (5%,). Post operative complications after distraction osteogenesis were pin tract infections in 8 patients (40%), Axial deviations in 6 patients (30%), foot equinus in 4 patients (20%) and refracture in 1 patient (5%). CONCLUSION Uniplanner locally manufactured (NASEER & AWAIS) External Fixator for distraction osteogenesis is cheap, easy to apply and gives excellent and comparable results in tibial bone defects.
منابع مشابه
Ilizarov bone transport after massive tibial trauma: Case report
INTRODUCTION This is a case report of extreme lengthening of the tibia of about 14.5cm using bone transport technique following road traffic accident trauma to the lower limbs. The management of the subsequent massive skeletal defects was challenging to orthopedic surgeons. Based on reported cases, the highest tibial lengthening was 22cm using bifocal transport, while the highest unifocal tibia...
متن کاملTen year experience with use of Ilizarov bone transport for tibial defects.
Tibial defects greater than 4 cm and secondary to high-energy trauma or debridement for infected nonunion pose a significant challenge to the treating orthopaedic surgeon. Twelve patients who had been treated with Ilizarov bone transport for tibial defects over the past ten years were retrospectively reviewed. All patients were male with an average age of thirty-two. Ten of the twelve limbs wer...
متن کاملIs acute compression and distraction superior to segmental bone transport techniques in chronic tibial osteomyelitis ? Comparison of Distraction Osteogenesis Techniques.
Treatment of tibial osteomyelitis with infected, necrotic, unstable bone segments (Cierny-Mader Type IV local osteomyelitis) includes débridement and segmental resection, which results in long bone defects. Reconstruction may be with distraction osteogenesis. Segmental bone transport and acute compression and distraction techniques are two main distraction osteogenesis techniques used in the tr...
متن کاملA novel technique of managing compound tibia fractures with severe bone defects using the Ilizarov technique: A case series
Introduction: One of the commonly encountered surgical dilemmas for most orthopaedic trauma surgeons is the management of compound tibia fractures with significant bone defects. We used the Ilizarov technique to solve this complex problem using an ilizarov fixator over an intramedullary tibia nail. We present a case series of five such patients with compound tibia fractures with significant bon...
متن کاملCircular external fixation and cemented PMMA spacers for the treatment of complex tibial fractures and infected nonunions with segmental bone loss.
PURPOSE The purpose of this study was to compare the outcome of combined circular external fixation and cemented polymethylmethacrylate (PMMA) spacer application between a cohort of patients with grade 3 open fractures and infected tibial nonunions and concomitant segmental bone loss. METHODS The study was designed as a retrospective cohort study. All patients who were treated for complex tib...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of Ayub Medical College, Abbottabad : JAMC
دوره 17 3 شماره
صفحات -
تاریخ انتشار 2005