Abstract-The problem that we investigate in the present paper is the improvement of the analysis of the primary tumor mass, in patients with advanced neuroblastoma, using X-ray computed tomography (CT) exams
نویسندگان
چکیده
The problem that we investigate in the present paper is the improvement of the analysis of the primary tumor mass, in patients with advanced neuroblastoma, using X-ray computed tomography (CT) exams. To achieve this goal, we propose a methodology for the estimation of the histological content of the mass that comprises a technique for semi-automatic segmentation of the primary tumor mass in CT images of neuroblastoma and a statistical method to estimate, from segmented CT images, the histological composition of the primary tumor. The results of the method are compared with the results of histological analysis of surgically resected tumor mass.
منابع مشابه
Patient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملHistogram analysis- a useful tool for tissue characterization in brain CT
Introduction: Pixel value in computed tomography (CT) gives the average linear attenuation coefficient of the scanned material in the path of the x-ray beam, being normalized to that of water. It is known that attenuation coefficient or HU value is a function of the chemical characteristic of the material and of the x-ray energy. The CT image shows the HU value by a shade of gr...
متن کاملComputed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends
The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -