Multi-laboratory inter-institute reproducibility study of IVOCT and IVUS assessments using published consensus document definitions.

نویسندگان

  • Edouard Gerbaud
  • Giora Weisz
  • Atsushi Tanaka
  • Manabu Kashiwagi
  • Takehisa Shimizu
  • Lin Wang
  • Christiano Souza
  • Brett E Bouma
  • Melissa J Suter
  • Milen Shishkov
  • Giovanni J Ughi
  • Elkan F Halpern
  • Mireille Rosenberg
  • Sergio Waxman
  • Jeffrey W Moses
  • Gary S Mintz
  • Akiko Maehara
  • Guillermo J Tearney
چکیده

AIMS The aim of this study was to investigate the reproducibility of intravascular optical coherence tomography (IVOCT) assessments, including a comparison to intravascular ultrasound (IVUS). Intra-observer and inter-observer variabilities of IVOCT have been previously described, whereas inter-institute reliability in multiple laboratories has never been systematically studied. METHODS AND RESULTS In 2 independent laboratories with intravascular imaging expertise, 100 randomized matched data sets of IVOCT and IVUS images were analysed by 4 independent observers according to published consensus document definitions. Intra-observer, inter-observer, and inter-institute variabilities of IVOCT qualitative and quantitative measurements vs. IVUS measurements were assessed. Minor inter- and intra-observer variability of both imaging techniques was observed for detailed qualitative and geometric analysis, except for inter-observer mixed plaque identification on IVUS (κ = 0.70) and for inter-observer fibrous cap thickness measurement reproducibility on IVOCT (ICC = 0.48). The magnitude of inter-institute measurement differences for IVOCT was statistically significantly less than that for IVUS concerning lumen cross-sectional area (CSA), maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters (P < 0.001, P < 0.001, P < 0.001, P = 0.02, P < 0.001, and P = 0.01, respectively). Minor inter-institute measurement variabilities using both techniques were also found for plaque identification. CONCLUSION In the measurement of lumen CSA, maximum and minimum lumen diameters, stent CSA, and maximum and minimum stent diameters by analysts from two different laboratories, reproducibility of IVOCT was more consistent than that of IVUS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification of coronary plaque sub-types using virtual histology intravascular ultrasound is affected by inter-observer variability and differences in plaque definitions.

BACKGROUND Recent studies show that virtual histology intravascular ultrasound (VH-IVUS) can identify plaques at high risk of rupture, such as thin-capped fibroatheromata, raising the possibility of immediate targeted intervention. However, plaque classification entails border recognition and subjective assessment of plaque architecture, introducing inter-observer variability without confirmati...

متن کامل

Reproducibility of the STARD checklist: an instrument to assess the quality of reporting of diagnostic accuracy studies

BACKGROUND In January 2003, STAndards for the Reporting of Diagnostic accuracy studies (STARD) were published in a number of journals, to improve the quality of reporting in diagnostic accuracy studies. We designed a study to investigate the inter-assessment reproducibility, and intra- and inter-observer reproducibility of the items in the STARD statement. METHODS Thirty-two diagnostic accura...

متن کامل

Development and Validation of an Internationally-Standardized, High-Resolution Capillary Gel-Based Electrophoresis PCR-Ribotyping Protocol for Clostridium difficile

PCR-ribotyping has been adopted in many laboratories as the method of choice for C. difficile typing and surveillance. However, issues with the conventional agarose gel-based technique, including inter-laboratory variation and interpretation of banding patterns have impeded progress. The method has recently been adapted to incorporate high-resolution capillary gel-based electrophoresis (CE-ribo...

متن کامل

Ex vivo validation of 45 MHz intravascular ultrasound backscatter tissue characterization.

AIMS The objectives of the present study are to describe the algorithm for VH(®) IVUS using the 45-MHz rotational IVUS catheter and the associated ex vivo validation in comparison to the gold standard histology. METHODS AND RESULTS The first phase of the present study was to construct the 45 MHz VH IVUS algorithm by using a total of 55 human coronary artery specimens [111 independent coronary...

متن کامل

تفسیر نتایج ایمنوهیستوشیمی بیان HER2/neu در سرطان مهاجم پستان: بررسی توافق بین مشاهده‌کنندگان و در دو بار مشاهده توسط یک نفر

    Background and Aim: The accurate determination of HER-2 in invasive breast cancer has become a critical issue, particularly in context of the results of Herceptin adjuvant therapy. The aim of this study was to evaluate inter- and intraobserver reproducibility of assessment of HER2/neu immunostaining in invasive breast cancerMaterials and Methods: This study was cross sectional and the conve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal cardiovascular Imaging

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 2016