The assessment of the automatic exposure control system for mammography x-ray machine
نویسندگان
چکیده
In the U.S., performance assessment on the Automatic Exposure Control system (AEC) is managed according to the Mammography Quality Standards Act (MQSA). However, The AEC is not available in the performance assessment conducted in Korea. Also, there is no study made on the performance of the automatic exposure control system for mammography in Korea. For this reason, this study examined the performance of the automatic exposure control system for mammography that was clinically used in the Incheon area. Result showed that the difference of the mean optical density was 0.79 ∼ 2.81. This implies that some devices caused unnecessary x-ray exposure to patients. Furthermore, only 61.5% of the entire experimental device was shown to be satisfactory in terms of change in mean optical density. Moreover, in terms of the subject’s thickness, change in radiographic density was shown to be severe among lower X-ray tube voltage while there was severe density change in X-ray image depending on X-ray tube voltage among the subjects with more thickness. Therefore, it is suggested to provide performance management on the AEC for mammography.
منابع مشابه
Calculation of the X-Ray Spectrum of a Mammography System with Various Voltages and Different Anode-Filter Combinations Using MCNP Code
Introduction One of the best methods in the diagnosis and control of breast cancer is mammography. The importance of mammography is directly related to its value in the detection of breast cancer in the early stages, which leads to a more effective treatment. The purpose of this article was to calculate the X-ray spectrum in a mammography system with Monte Carlo codes, including MCNPX and MCNP5...
متن کاملCalculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography
Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...
متن کاملQuality assessment of conventional X-ray diagnostic equipment by measuring X-ray exposure and tube output parameters in Great Khorasan Province, Iran
Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...
متن کاملImpact of quality control on radiation doses received by patients undergoing abdomen X-ray examination in ten hospitals
ABSTRACT Background: The X-ray machines used for radiodiagnosis should meet certain quality assurance (QA) programmes . These are necessary to have good quality radiographs at reasonably low exposure to patients. Materials and Methods: Dose reduction methods in abdomen X-ray examination were carried out in 10 hospitals in Tehran. This paper presents the work, which was implemented on 200 ...
متن کاملLevel of exposure to X-Ray in security gates of Tehran’s Imam Khomeini airport
X-Ray is an ionizing electromagnetic radiation with a wide spectrum. A setting where this radiation is widely used is airport security units. This study was conducted to measure the level of momentary exposure to X-Ray in operators and personnel working in security gates of Imam Khomeini airport. In this cross-sectional study, the X-Ray machines used in security gates of Imam Khomeini airport a...
متن کامل