Distribution of angiographic measures of restenosis after drug-eluting stent implantation.
نویسندگان
چکیده
BACKGROUND A bimodal distribution of measures of restenosis has been demonstrated at 6-8 months after bare metal stent implantation. Drug-eluting stent (DES) treatment has attenuated the impact of certain factors (eg, diabetes) on restenosis but its effect on the distribution of indices of restenosis is not known. OBJECTIVE To perform a detailed analysis of the metrics of restenosis indices after DES implantation. Design, settings, PATIENTS Prospective observational study of patients undergoing DES implantation (Cypher, sirolimus-eluting stent; or Taxus, paclitaxel-eluting stent) at two German centres, with repeat angiography scheduled at 6-8 months after coronary stenting. MAIN OUTCOME MEASURES In-stent late luminal loss (LLL) and in-segment percentage diameter stenosis (%DS) as determined by quantitative coronary angiography at recatheterisation. RESULTS Paired cineangiograms were available for 2057 patients. Overall mean (SD) LLL was 0.31 (0.50) mm; mean (SD) %DS was 30.3 (15.7)%. Distribution of both LLL and %DS differed significantly from normal (Kolmogorov-Smirnov test; p<0.001 for each). For both parameters a mixed distribution model better described the data (likelihood ratio test with 3df; p<0.001 for each). This consisted of two normally distributed subpopulations with means (SD) of 0.10 (0.25) mm and 0.69 (0.60) mm for LLL, and means (SD) of 22.2 (8.6)% and 40.1 (16.6)% for %DS. The results were consistent across subgroups of DES type, "on-label" versus "off-label" indication, and presence or absence of diabetes. CONCLUSIONS LLL and %DS at follow-up angiography after DES implantation have a complex mixed distribution that may be accurately represented by a bimodal distribution model. The introduction of DES treatment has not resulted in elimination of a variable propensity to restenosis among subpopulations of patients with stented lesions.
منابع مشابه
Angiographic patterns of restenosis after sirolimus-eluting stent implantation.
BACKGROUND Large-scale randomized trials demonstrate a high proportion of focal restenosis after drug-eluting stent (DES) implantation. On the other hand, recent reports have shown that in real-world practice a significant proportion of the restenosis is non-focal when DESs are used in unselected lesions. The present study evaluated angiographic patterns of restenosis after sirolimus-eluting st...
متن کاملIntravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation.
AIMS In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. METHODS AND RESULTS SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-mon...
متن کاملPredictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents.
BACKGROUND The efficacy of drug-eluting stents in reducing restenosis risk has not been uniform across patient subsets. Identifying predictive factors of restenosis may help improve outcomes after percutaneous coronary interventions. METHODS AND RESULTS All patients who underwent successful implantation of sirolimus- or paclitaxel-eluting stents in native vessels for de novo lesions between A...
متن کاملOverview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملPaclitaxel-eluting balloons for sirolimus-eluting stent restenosis.
We read with interest the randomized study by Habara et al. (1) comparing paclitaxel-eluting balloon (PB) (n 25) with convenional balloon (BA) (n 25) in patients suffering from sirolimusluting stent (SES) in-stent restenosis (ISR). In these patients, PB rovided a dramatic improvement in angiographic parameters at ate follow-up, compared with BA. This information is timely, ecause ISR after drug...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Heart
دوره 95 19 شماره
صفحات -
تاریخ انتشار 2009