A randomized comparison of microtip and air-charged catheter for the measurement of maximum urethral closure pressure.
نویسندگان
چکیده
BACKGROUND Measurements of maximum urethral closure pressure (MUCP) are a part of urodynamic investigations preceding an incontinence surgery and a part of urethral function tests. OBJECTIVES The aim of the study was to compare maximum urethral closure pressure determined by a microtip catheter with those measured by an air-charged catheter. MATERIAL AND METHODS A prospective randomized study in a tertiary referral centre. 122 female patients with urodynamic stress incontinence were randomly assigned to have their urethral pressure profiles measured at rest by both microtip and air-charged catheters. INTERVENTION AND MEASUREMENTS Each patient had three measurements taken by each catheter type. Means of the measurements were compared with regard to correlation and repeatability. For statistical analysis, an approach proposed by Bland-Altman was applied to assess the agreement between the two techniques. RESULTS Correlation coefficient between MUCP by the air-charged and the microtip catheter was r=0.8507 (95% CI 0.7928 - 0.8934; p<0.0001). MUCP by the air-charged catheter was significantly lower than MUCP measured by the microtip catheter. The two-tailed p value was <0.0001, considered extremely significant. (95% CI of the differences; mean difference = -3.033; mean of paired differences -3.730 to -2.335). Discrepancies between measurements of the microtip and the air-charged catheters suggest good agreement between the two catheters since the mean difference was 2.8 cmH2O and the 95% CI of agreement were narrow with -0.03319 to 0.3151. CONCLUSION Air-charged catheters give lower readings for MUCP than microtip catheters with a good agreement between the two catheters.
منابع مشابه
Comparison of microtransducer and fiberoptic catheters for urodynamic studies.
OBJECTIVE To assess the validity and reproducibility of a fiberoptic transducer urodynamic catheter for urethral closure pressure profiles and leak point pressure determination, using a microtransducer catheter as the standard. METHODS Ninety women without significant pelvic organ prolapse underwent urodynamic evaluations with both fiberoptic and microtransducer catheters. Maximal urethral cl...
متن کاملThe effect of prostatic regional block on post-operative urethral catheter discomfort in TURP surgery: a randomized double-blind clinical trial
Background: Transurethral resection of the prostate (TURP) is a routine surgery for of benign prostatic hyperplasia treatment but this surgery is accompanied by unpleasant sensation due to the presence of a urinary catheter. In this study, the role of Bupivacaine for localized blockade of the prostate in patients undergoing prostate resection under general anesthesia was investigated. Materials...
متن کاملEvaluation of urodynamic procedures in female cats anesthetized with low and high doses of isoflurane and propofol.
OBJECTIVE To compare effects of isoflurane and propofol on the cystometrogram and urethral pressure profile (UPP) in healthy female cats. ANIMALS 6 healthy female cats. PROCEDURES Cats were anesthetized, and a consistent plane of anesthesia was maintained with low and high doses of isoflurane and propofol. A 6-F double-lumen urinary catheter was placed aseptically in the urethra for cystome...
متن کاملInvolvement of reflex urethral closure mechanisms in urethral resistance under momentary stress condition induced by electrical stimulation of rat abdomen.
A novel method for evaluating the urethral resistance during abrupt elevation of abdominal pressure was developed in spinalized female rats under urethane anesthesia. Electrical stimulation of abdominal muscles for 1 s induced increases in both the intra-abdominal and the intravesical pressure in a stimulus-dependent manner, and the bladder response was almost lost when the abdomen was opened. ...
متن کاملMeasurement of urethral closure function in women with stress urinary incontinence.
PURPOSE We assessed the use of urethral pressure reflectometry in detecting pressure increases in the female urethra and compared the usefulness of urethral pressure reflectometry vs urethral pressure profilometry in a pharmacodynamic intervention study. MATERIALS AND METHODS In this randomized, double-blind, placebo controlled, crossover study 17 women with stress urinary incontinence or mix...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Ginekologia polska
دوره 83 8 شماره
صفحات -