Effect of counting errors on immunoassay precision.

نویسندگان

  • G G Klee
  • G Post
چکیده

Using mathematical analysis and computer simulation, we studied the effect of gamma scintillation counting error on two radioimmunoassays (RIAs) and an immunoradiometric assay (IRMA). To analyze the propagation of the counting errors into the estimation of analyte concentration, we empirically derived parameters for logit-log data-reduction models for assays of digoxin and triiodothyronine (RIAs) and ferritin (IRMA). The component of the analytical error attributable to counting variability, when expressed as a CV of the analyte concentration, decreased approximately linearly with the inverse of the square root of the maximum counts bound. Larger counting-error CVs were found at lower concentrations for both RIAs and the IRMA. Substantially smaller CVs for overall assay were found when the maximum counts bound progressively increased from 500 to 10,000 counts, but further increases in maximum bound counts resulted in little decrease in overall assay CV except when very low concentrations of analyte were being measured. Therefore, RIA and IRMA systems based in duplicate determinations having at least 10,000 maximum counts bound should have adequate precision, except possibly at very low concentrations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

تاثیر استرس بر توجه بینایی انتخابی با نگاه به عامل شخصیتی برونگرایی

Introduction: This study was devoted to investigating the effect of stress on visual selective attention according to Extraversion (E) moderating effect. Method: The sample group was selected with respect to neuropsychological control variables by multi-session random sampling from unmarried male Tehran universities’ students (60 subjects in three equal groups (20 subjects in each group) two ...

متن کامل

Automated particle-counting immunoassay for digoxin.

We describe a non-radioisotopic automated immunoassay for serum digoxin in the therapeutic range at 50 samples per hour by use of the particle-counting immunoassay technique and a special reagent, rheumatoid factor. Digoxin is determined by evaluating its inhibitory activity on the agglutination of digoxin-coated latex particles. The agglutinating system consists of the anti-digoxin IgG mixed w...

متن کامل

A Comparison of Thin Plate and Spherical Splines with Multiple Regression

Thin plate and spherical splines are nonparametric methods suitable for spatial data analysis. Thin plate splines acquire efficient practical and high precision solutions in spatial interpolations. Two components in the model fitting is considered: spatial deviations of data and the model roughness. On the other hand, in parametric regression, the relationship between explanatory and response v...

متن کامل

تأثیر استرس بر توجه انتخابی بینایی با نگاه به عامل شخصیتی وظیفه‌شناسی

AbstractObjectives: The aim of this research was to investigate the effect of stress on visual selective (focused) attention regarding the moderating effect of personality factor of conscientiousness. Method: 60 subjects were chosen by multi-stage random sampling method with respect to personality and neuropsychological criteria of the research and were placed in three equal groups (two experim...

متن کامل

The Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods

Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 35 7  شماره 

صفحات  -

تاریخ انتشار 1989