Transcatheter Closure of Patent Ductus Arteriosus: The Penang Hospital's Experience.

نویسندگان

  • A R Amir Hamzah
  • C A Tiow
  • G T Koh
  • A M Sharifah
چکیده

Transcatheter closure of small and moderate sizes of Patent Ductus Arteriosus (PDA) is a standard and well accepted form of treatment. The aim of this study is to describe the experience of transcatheter closure of PDA in Penang Hospital. All patients who underwent transcatheter closure of PDA at our institution between 20th January 2006 and 27th June 2008 were retrospectively identified and studied. There were a total of 66 patients who had undergone transcatheter closure of PDA during this period which comprised of 24 male and 42 female. The PDA was closed by Amplatzer Duct Occluder (ADO) in 31 patients, Gianturco coil in 29 patients and other types of devices in 6 patients. There were 4 patients (6%) who had developed acute complication during the procedure (3 of them developed coil embolization and 1 had bleeding from puncture site). The PDA was successfully close in 95.5% of the study population without any residual PDA shunting. All the patients were alive but 5 of them (4.5%) have some abnormalities (2 has mild left pulmonary stenosis, 3 has small residual). Comparison between ADO and Gianturco coil revealed no significant difference in the outcome. Transcatheter closure of PDA has proven to be safe and effective with good midterm outcome. There was no significant difference between Amplatzer Ductal Occluder and Gianturco coil in term of the outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter closure of the patent ductus arteriosus.

Patent ductus arteriosus (PDA) is one of the most common congenital heart defects. Although surgery is still required in symptomatic neonates, the majority of older infants and children can undergo safe and effective transcatheter device closure on an out-patient basis. First described in 1967, over the past four decades, numerous devices have been specifically developed for this purpose. This ...

متن کامل

Sequential Transcatheter Closure of a Patent Ductus Arteriosus and a Muscular Ventriculer Septal Defect in a Child

Due to the developing technology in pediatric catheterization and increasing experience of pediatric cardiologists, currently transcatheter closure of multiple cardiac defects has become available. The present case report describes a patient who successfully underwent sequential transcatheter closure of patent ductus arteriosus (PDA) and muscular ventricular septal defect (VSD). Transcatheter c...

متن کامل

Transcatheter closure of patent ductus arteriosus.

More than three decades have passed since the introduction of transcatheter devices for closure of patent ductus arteriosus, and many occluders have been made available since then. The ideal requirements of any procedure are a user-friendly technique, optimum success rate, no residual anomaly, minimal morbidity/mortality, and comparability or superiority to the existing conventional modality of...

متن کامل

Intravenous Paracetamol and Patent Ductus Arteriosus Closure

Background: Standard medical treatments for patent ductus arteriosus (PDA) closure are, including indomethacin/ibuprofen and surgical ligation. Nowadays, a new strategy to close PDA is the use of paracetamol. The present study aimed to describe the use of intravenous (IV) paracetamol for PDA closure in neonates who present a contraindication to ibuprofen or ibuprofen failure with no possibility...

متن کامل

Transcatheter closure of post-operative residual ventricular septal defect using a patent ductus arteriosus closure device in an adult: a case report.

Transcatheter closure of perimembranous and muscular ventricular septal defect (VSD) has been performed widely and it has more advantages compare to surgery. However, transcatheter closure of residual VSD post operation of complex congenital heart disease is still challenging because of the complexity of anatomy and concern about device stability, so the operator should meticulously choose the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Medical journal of Malaysia

دوره 66 1  شماره 

صفحات  -

تاریخ انتشار 2011