A numerical investigation of flame liftoff, stabilization, and blowout

نویسندگان

  • Alejandro M. Briones
  • Suresh K. Aggarwal
  • Viswanath R. Katta
چکیده

The effects of fuel stream dilution on the liftoff, stabilization, and blowout characteristics of laminar nonpremixed flames NPFs and partially premixed flames PPFs are investigated. Lifted methane-air flames were established in axisymmetric coflowing jets. Because of their flame suppression characteristics, two predominantly inert agents, CO2 and N2, were used as diluents. A time-accurate, implicit algorithm that uses a detailed description of the chemistry and includes radiation effects is used for the simulations. The predictions are validated using measurements of the reaction zone topologies and liftoff heights of both NPF and PPF. While an undiluted PPF is stabilized at the burner rim, characterized by significant radical destruction and heat loss to the burner, the corresponding undiluted NPF is lifted and stabilized in a low-velocity region extending from the wake of the burner. Detailed comparison of diluted NPF with PPF reveals that the base structures of both the flames are similar and exhibit a double flame structure in the near-field region, where the flame stabilization depends on a balance between the reaction rate and the scalar dissipation rate, which could also be interpreted as a balance between the edge-flame speed undergoing its local scalar dissipation rate and the local flow velocity. As diluent concentration is increased, the flames become weaker, move downstream along the stoichiometric mixture fraction line, and stabilize at a location where they can find a local flow field that has a lower scalar dissipation rate. Further increase of the diluent concentration moves the flames further downstream into the far-field region, where both the NPF and PPF exhibit a triple flame structure, and the flame stabilization mechanism also involves a balance between the triple flame speed and local flow velocity. The PPFs, however, shift to a higher liftoff height and blow out at a lower diluent concentration compared to the NPF, which can withstand larger amounts of dilution. In addition, both NPF and PPF are stabilized at lower liftoff heights and blowout at a lower diluent concentration, when they are diluted with N2 compared to that with CO2. The observed effects of fuel stream dilution and partial premixing on flame liftoff and blowout can be explained using the existing flame stabilization theories. © 2006 American Institute of Physics. DOI: 10.1063/1.2191851

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flame Stabilization Using a Pulsed Plasma Discharge in Subsonic Flow

Stable combustion in a harsh environment, such as lean fuel concentration and/or low temperature conditions, is attractive because of its low emissions. However, such flames suffer from lack of stability. In our research, an AC plasma discharge is applied to a lifted jet flame to increase the stability of the flame. Two types of discharges are utilized for this experiment. First, a single elect...

متن کامل

Study of Liftoff Mechanism of Nonpremixed Jet Flame near Unity Schmidt Number

Nonpremixed jet flames of dimethyl ether (DME) were studied both experimentally and theoretically to investigate flame liftoff near unity Schmidt number. It was found experimentally that although the DME nonpremixed flames have a Schmidt number larger than unity it cannot be lifted directly by increasing the flow rate. Lifted flames can only be established by igniting the mixture in a narrow re...

متن کامل

Suppression of fuel and air stream diluted methane–air partially premixed flames in normal and microgravity

The effects of fuel and air stream dilution (ASD) with carbon dioxide on the suppression of normal and microgravity laminar methane–air partially premixed coflow jet flames were experimentally and numerically investigated. Experiments were conducted both in our normal-gravity laboratory and at the NASA Glenn Research Center 2.2 s drop tower. Measurements included flame topology and liftoff heig...

متن کامل

Investigation of Air Turbulence Intensity Effect on the Flame Structure in Different Flame Holder Geometry

In this paper, the effect of air turbulence intensity on the flame structure in various radii and lengths of a flame holder numerically studied. Finite volume method is used to solve the governing equations. The obtained numerical results using realizable k-ε and β-PDF models show a good agreement with the experimental data. The results show that flame holder with greater lengths yield shorter ...

متن کامل

Liftoff characteristics of partially premixed flames under normal and microgravity conditions

An experimental and computational investigation on the liftoff characteristics of laminar partially premixed flames (PPFs) under normal (1-g) and microgravity (μ-g) conditions is presented. Lifted methane–air PPFs were established in axisymmetric coflowing jets using nitrogen dilution and various levels of partial premixing. The μ-g experiments were conducted in the 2.2-s drop tower at the NASA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006