Computational wear simulation of patellofemoral articular cartilage during in vitro testing.

نویسندگان

  • Lingmin Li
  • Shantanu Patil
  • Nick Steklov
  • Won Bae
  • Michele Temple-Wong
  • Darryl D D'Lima
  • Robert L Sah
  • Benjamin J Fregly
چکیده

Though changes in normal joint motions and loads (e.g., following anterior cruciate ligament injury) contribute to the development of knee osteoarthritis, the precise mechanism by which these changes induce osteoarthritis remains unknown. As a first step toward identifying this mechanism, this study evaluates computational wear simulations of a patellofemoral joint specimen wear tested on a knee simulator machine. A multibody dynamic model of the specimen mounted in the simulator machine was constructed in commercial computer-aided engineering software. A custom elastic foundation contact model was used to calculate contact pressures and wear on the femoral and patellar articular surfaces using geometry created from laser scan and MR data. Two different wear simulation approaches were investigated--one that wore the surface geometries gradually over a sequence of 10 one-cycle dynamic simulations (termed the "progressive" approach), and one that wore the surface geometries abruptly using results from a single one-cycle dynamic simulation (termed the "non-progressive" approach). The progressive approach with laser scan geometry reproduced the experimentally measured wear depths and areas for both the femur and patella. The less costly non-progressive approach predicted deeper wear depths, especially on the patella, but had little influence on predicted wear areas. Use of MR data for creating the articular and subchondral bone geometry altered wear depth and area predictions by at most 13%. These results suggest that MR-derived geometry may be sufficient for simulating articular cartilage wear in vivo and that a progressive simulation approach may be needed for the patella and tibia since both remain in continuous contact with the femur.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Predicting in Vitro Articular Cartilage Wear in the Patellofemoral Joint Using Finite Element Modeling

The mechanism by which altered knee joint motions and loads (e.g., following anterior cruciate ligament injury) contribute to the development of knee osteoarthritis (OA) is not well understood. One hypothesis is that articular cartilage degradation is initiated when altered knee kinematics increase loading on certain regions of the articular surfaces and decrease loading on other regions [1]. A...

متن کامل

The Effect of Shoe Type and Load Carrying on Electromyographic Activity of Lower Extremity Muscles during Stair Ascent and Descent

Objective Stair ascent and descent is an essential movement task in daily life in which individuals are subjected to repetitive impact forces. The purpose of this study was to evaluate the intensity of Electromyographic (EMG) activity in lower extremity muscles of healthy young men during stair ascent and descent task wearing different type of shoes and carrying loads. Methods Nine men with a ...

متن کامل

Traumatic Chondral Lesions of the Knee Diagnosis and Treatment

1.1 Anatomy and knee joint function The knee joint is classified as a modified hinge joint, with its structure providing a highly mobile and complex joint (fig.1). It consists of two condylar joints between the medial and lateral condyles of the femur and the corresponding plateaus of the tibia, and anteriorly a synovial plane patellofemoral joint. The articular surface of the knee is covered b...

متن کامل

Influence of the meniscus on friction and degradation of cartilage in the natural knee joint.

BACKGROUND Total meniscectomy has been shown to cause early-onset arthritis in the underlying cartilage and bone in the knee joint, demonstrating that the meniscus plays an important protective role in the load carrying capacity. Relationships between friction and wear in synovial joints are complex due to the biphasic nature of articular cartilage and the time dependency of tribological respon...

متن کامل

An in vitro study of cartilage-meniscus tribology to understand the changes caused by a meniscus implant.

Active lifestyles increase the risk of meniscal injury. A permanent meniscus implant of polycarbonate urethane (PCU) is a promising treatment to postpone/prevent total knee arthroplasty. Study of the changes in articular cartilage tribology in the presence of PCU is essential in developing the optimum meniscus implant. Therefore, a cartilage-meniscus reciprocating, sliding model was developed i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 44 8  شماره 

صفحات  -

تاریخ انتشار 2011