Stress Errors Associated with Miniaturization of X-Ray Stress Analyzer

نویسندگان

  • Toru GOTO
  • Yu GONG
چکیده

The problems caused by miniaturization of the goniometer are discussed from the viewpoint of the stress error caused by mis-setting of the specimen and misalignment of the collimator and detector for the Q assembly X-ray stress analyzer using a position sensitive detector. The stress errors were calculated using a model and a simulation method. It was found that they tend to increase with the decrease in goniometer radius and effective collimator length. Therefore, the minimum size of the analyzer was investigated for a given value of total error. In conclusion, it is believed that the size for the goniometer radius and the collimator effective length could possibly be optimized. An analyzer of the single exposure method was also studied and found sensitive to the misalignment of the collimator and detector, but not to specimen mis-setting for miniaturization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

STRESS ERRORS ASSOCIATED WITH MINIATURIZATION OF psi ASSEMBLY X-RAY STRESS ANALYZERS

Using a model and a simulation method, the problems caused by miniaturization of goniometers are discussed from the viewpoint of the stress error caused by systematic errors including the mis-setting of the specimen and the misalignments of the collimator and detector of the Ψ assembly X-ray stress analyzer with a position sensitive detector. As a concluion, it was found that stress errors incr...

متن کامل

Determination of Residual Stress of PACVD Nanostructure TiN Coatings by GIXRD Method

In this study, thin layers of titanium nitride (TiN) were deposited on H13 steel substrates at different duty cycles and temperature of 520 ˚C using plasma assisted chemical vapor deposition (PACVD). Uniaxial residual stress was calculated by X-ray diffraction (XRD) and Sin2 Ψ method. Then the residual stress of the samples were measured by Grazing Incidence X-ray Diffraction (GIXRD) method and...

متن کامل

Experimental and Numerical Study of Residual Stress in the WC-12Co HVOF Sprayed Coatings

Thermally sprayed coatings are intrinsically associated with residual stresses in the deposits. These stresses are varied in nature and magnitude, and have a pronounced effect on the mechanical behavior of the system. In the current study, WC-12Co coatings were deposited using HVOF thermal spraying. The sin2ψ method was used to evaluate the through thickness residual stress by means ...

متن کامل

Residual stresses in a soda-lime-silica glass-ceramic

The present study was undertaken to test the validity of existing models for: (i) the residual internal stresses which arise due to thermal and elastic mismatch in duplex systems; and (ii) the critical particle diameter for spontaneous cracking. The specimens studied were bulk nucleated, partially crystallized 17.20Na,0-32.09Ca0-4.12Si0,-2.59P,O, (mol%) glasses. The residual stress was determin...

متن کامل

The assessment of function, histopathological changes, and oxidative stress in liver tissue due to ionizing and non-ionizing radiations

Background: Compared to past decades, humans are exposed to rapidly increasing levels of radiofrequency electromagnetic radiations (RF-EMF). Despite numerous studies, the biological effects of human exposure to different levels of RF-EMF are not fully understood, yet. This study aimed to evaluate the bioeffects of exposure to "900/1800 MHz" and “2.4 GHz" RF-EMFs, and x-rays as well as their pot...