Transient tritanopia in migraine: evidence for a large-field retinal abnormality in blue-yellow opponent pathways.
نویسندگان
چکیده
PURPOSE To determine whether the magnitude of transient tritanopia (TT) differs between migraine and control groups. TT is a retinal phenomenon characterized by a paradoxical reduction in sensitivity to short-wavelength (purple) stimuli after extinction of long-wavelength (yellow) adapting displays. A group difference in the magnitude of TT would provide evidence for a retinal contribution to the S-cone-specific color-processing abnormalities that have been reported in migraine. METHODS Thirty-two migraineurs and 32 age- and sex-matched control participants were tested with a four-alternative, forced-choice procedure to determine S-cone increment and decrement detection thresholds before and after adaptation to a long-wavelength (yellow) display and a neutral (white) display. Migraine history, migraine triggers, and pattern sensitivity were also assessed. RESULTS Both groups' detection thresholds for increment (purple) S-cone stimuli were increased after extinction of the long-wavelength adapting display compared with the neutral display, demonstrating TT. This loss of sensitivity was significantly greater in the migraine group. In contrast, loss of sensitivity to decrement (yellow) S-cone stimuli was less marked and did not differ between the groups. The magnitude of TT correlated positively with indices of pattern sensitivity and susceptibility to visually triggered migraines but not with migraine history. CONCLUSIONS These results demonstrate that abnormalities in a specific retinal circuit contribute to decreased short-wavelength sensitivity after adaptation in migraine. As thresholds did not correlate with indices of migraine history, it is unlikely that this finding reflects cumulative damage induced by repeated migraine episodes.
منابع مشابه
The Evaluation of Yellow vs. Blue Color Contrast Sensitivity pre and Post LASIK
Introduction: contrast sensitivity is one of the most important psychophysical tests that may be used for the evaluation of refractive state of eye and retinal image quality. Yellow vs. blue color contrast sensitivity may be more suitable in this regard. Materials and Methods: thirty myopic eyes were considered in this study. Yellow vs. blue color contrast sensitivity was evaluated under the sa...
متن کاملEffects of ageing on postreceptoral short-wavelength gain control: Transient tritanopia increases with age
We investigated the effect of ageing on the neural gain control in the short-wavelength opponent channel. In order to tackle specifically postreceptoral changes, we determined the effect of ageing on transient tritanopia, a paradoxical and transient reduction of short-wavelength sensitivity after the presentation of a long-wavelength adapting light. The results demonstrate an unexpected and sig...
متن کاملRods induce transient tritanopia in blue cone monochromats
Transient tritanopia is a cone-cone post-receptoral interaction between short-wavelength (S) cones and medium (M) and long (L) wavelength cones. Blue cone monochromats have rods and S cones of normal sensitivity but lack functional M/L cones. All blue cone monochromats tested (n = 8) show significant amounts of transient tritanopia mediated by rods. Attempts to find a similar rod-S cone interac...
متن کاملEffect of foveal tritanopia on reaction times to chromatic stimuli.
To investigate the effect of foveal inhomogeneities on sensitivity to chromatic stimuli, we measured simple reaction times (RTs) and detection thresholds to temporally and spatially blurred isoluminant stimuli at retinal eccentricities from 0 deg to 8 deg. Three color-normal subjects participated. Contrast gain was derived from the slope of the RT versus contrast function. With a Gaussian spati...
متن کاملON and OFF S-cone pathways have different long-wave cone inputs
Three experiments compared thresholds for S-cone increments and decrements under steady and transient adaptation conditions, to investigate whether stimuli of both polarities are detected by the same cone-opponent psychophysical mechanism. The results could not be accounted for by a standard model of the S-cone detection pathway [Polden & Mollon (1980) Proceedings of the Royal Society of London...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 47 11 شماره
صفحات -
تاریخ انتشار 2006