INTRODUCTION The purpose of this research was to study the effect of increased axial myopia, in non-glaucomatous eyes, and its correlation with ONH parameters, and RNFL thickness, using Cirrus HD 4000 SD-OCT. METHODS The myopia group included 86 eyes of 86 patients, while the control group involved 92 eyes of 92 patients, attending the Ophthalmology Outpatient Clinic in Minia University Hospital, between November 2013 and March 2015. ONH parameters and peripapillary RNFL thickness measurement were evaluated by using SD-OCT, selecting the standard optic disc cube 200 × 200. RESULTS The mean age of the myopia group was (36.55 ± 9.44), the mean spherical equivalent was (-12.70 ± 3.87 D), and the mean axial length was (27.88 ± 1.92 mm). The control group had mean age of (34.82 ± 8.87), mean spherical equivalent of -0.65 ± 0.41 D, and mean AL of (22.16 ± 0.82). A significant difference was reported between the two groups, regarding disc area (p = 0.01), rim area (p = 0.001), vertical C/D (p = 0.01), average C/D ratio (p = 0.001), average and temporal RNFL thickness (p = 0.0001, p = 0.001, respectively). CONCLUSION A significant difference was found between highly myopic non-glaucomatous eyes and the control group, regarding ONH parameters and RNFL thickness as measured by SD-OCT. As OCT magnification adjusted ONH parameters were larger, global and the temporal RNEL were thicker in the myopia group, those magnification adjusted parameters helped in an accurate evaluation of ONH and RNFL in highly myopic eyes, in order to avoid misdiagnosis of glaucoma in such eyes.
منابع مشابه
Clinical Applications of Optical Coherence Tomography in Ophthalmology
Assessment of the peripapillary nerve fiber layer and macular thickness can be determined in ophthalmology using optical coherence tomography (OCT). Decreased nerve fiber layer thickness and macular ganglion cell thickness in optic nerve ischemia have been correlated with visual field loss. OCT allows deep optic nerve head evaluation which helps understand pathophysiology of diseases. Furtherm...
متن کاملGanglion cell-inner plexiform layer and retinal nerve fiber layer thickness according to myopia and optic disc area: a quantitative and three-dimensional analysis
BACKGROUND To determine the influences of myopia and optic disc size on ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) thickness profiles obtained by spectral domain optical coherence tomography (OCT). METHODS One hundred and sixty-eight eyes of 168 young myopic subjects were recruited and assigned to one of three groups according to their spher...
متن کاملPredictors of normal optic nerve head, retinal nerve fiber layer, and macular parameters measured by spectral domain optical coherence tomography.
PURPOSE To evaluate the effects of signal strength, age, sex, optic disc size, and axial length on the normal optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular measurements with spectral domain optical coherence tomography (SD-OCT). METHODS In an observational, cross-sectional study, 119 eyes of 60 normal subjects of Indian origin underwent ONH, RNFL, and macular imaging w...
متن کاملThree-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.
PURPOSE To demonstrate high-speed, ultrahigh-resolution, 3-dimensional optical coherence tomography (3D OCT) and new protocols for retinal imaging. METHODS Ultrahigh-resolution OCT using broadband light sources achieves axial image resolutions of approximately 2 microm compared with standard 10-microm-resolution OCT current commercial instruments. High-speed OCT using spectral/Fourier domain ...
متن کاملThe influence of axial length on retinal nerve fibre layer thickness and optic-disc size measurements by spectral-domain OCT.
BACKGROUND To evaluate the influence of axial length on measurements of the retinal nerve fibre layer (RNFL) thickness and optic nerve head (ONH) parameters in healthy subjects. METHODS Using Cirrus HD-OCT, RNFL thickness and ONH parameters (disc and rim area) were measured in 15 short (<22.5 mm), 15 medium (22.51-25.5 mm) and 15 long (>25.51 mm) eyes. RESULTS The mean axial length was 21.5...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2017