Simulation studies of CZT Detectors as Gamma-Ray Calorimeter

نویسندگان

  • I. Jung
  • H. Krawczynski
چکیده

Several astrophysics and nuclear physics applications require the detection of photons in the energy range of keV up to several MeV with good position and energy resolution. For certain applications Cadmium Zinc Telluride (CZT) detectors might be the detector option of choice. Up to now, CZT detectors have mainly been used in the energy range between a few keV and ∼1 MeV. They operate at room temperature and achieve excellent position resolution and substantially better energy resolution than scintillation detectors. Furthermore, they can be built more compact and more economically than Ge detectors and do not require cryogenic cooling. In this paper, we describe the results of 3-D Monte Carlo simulations of a “CZT calorimeter” that can be used to detect photons in the keV to several MeV range. The main objective of these studies is to evaluate the feasibility of CZT calorimeters, to study their performance and detect and understand performance limiting factors. Such a calorimeter consists of many layers of closely packed pixellated CZT detector units. Our simulations of single detector units reproduce experimental results, indicating that our simulations capture the main factors that limit the performance of a detector unit. For a full calorimeter the limiting factors within a range from∼20 keV to∼10 MeV are: a) the fact, that the incident energy is not totally deposited within the detector area because secondary particles leave the detector against the direction from which the incident radiation enters, b) signal loss when the interaction is near the pixel edges and near the anodes. In this case signals which are induced in neighboring pixels are discarded when their intensities lie below the trigger threshold. c) the steep weighting potential gradient close to the anodes, which affects about 0.25 cm next to the anode and impairs there the correction of the depth of interaction (DOI). This effect dominates in thin detectors (0.5 cm). Understanding the limiting factors we come to the conclusion that 1 cm to 1.5 cm thick detector units can be used to build a calorimeter with good performance over the energy range from ∼20 keV to ∼10 MeV .

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel ZnO:Al contacts to CdZnTe for X- and gamma-ray detectors

CdZnTe (CZT) has made a significant impact as a material for room-temperature nuclear-radiation detectors due to its potential impact in applications related to nonproliferation, homeland security, medical imaging, and gamma-ray telescopes. In all such applications, common metals, such as gold, platinum and indium, have been used as electrodes for fabricating the detectors. Because of the large...

متن کامل

The Cadmium Zinc Telluride (CZT) Detector Array Innovation Pathway

This pathway describes the development of soft gamma-ray/hard x-ray detector arrays at NASA’s Goddard Space Flight Center (GSFC, or Goddard), through a collaboration between the gamma-ray spectroscopy group and the detector branch. The Cadmium Zinc Telluride (CdZnTe, or CZT) detectors which resulted from this decade-long development were first flown on the wildly successful SWIFT mission in 200...

متن کامل

CZT in Space Based Hard X-ray Astronomy: Background Predictions for EXIST

One of the key aspects of a detector material for space-borne hard X-ray and gamma-ray telescopes is the rate of prompt and delayed background events generated inside the material by charged and neutral particles striking the detector. These particles are Cosmic Rays, particles trapped in Earth’s magnetic field, and secondaries from Cosmic Ray interacting with the atmosphere and the spacecraft....

متن کامل

ar X iv : a st ro - p h / 97 12 35 9 v 1 1 J an 1 99 8 Proposed ( to ) EXIST : Hard X - ray Imaging All Sky Survey / Monitor

The hard x-ray (10-600 keV) sky is inherently time variable and yet has neither been surveyed nor been monitored with a sensitive imaging telescope. The Energetic X-ray Imaging Survey Telescope (EXIST) is a mission concept, proposed for MIDEX, which would conduct the first imaging all-sky hard x-ray survey as well as provide a sensitive all sky monitor (ASM). With ∼60% sky coverage each orbit, ...

متن کامل

Optical simulation and experimental measurement of gamma ray energy spectrum of plastic scintillators with different sizes

The application of large plastic scintillators is widely increasing in the different areas of industry, medicine and security due to technical and economic advantages. One of the main disadvantages of these detectors is the unknown position of Compton edge at gamma ray spectrum. In this research, GEANT4/GATE code has been used to simulate the gamma ray spectrum for different volumes of large pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006