Vancomycin by High-Flux Hemodialysis Membranes
نویسندگان
چکیده
Levels of vancomycin in serum are traditionally believed to be unaffected by hemodialysis. By both in vivo and in vitro techniques, the effects of a newer, more permeable dialyzer membrane on vancomycin concentrations were investigated. Six patients who were receiving vancomycin and undergoing maintenance hemodialysis with polyacrylonitrile dialyzer membranes had postdialysis levels in serum that were 63% of predialysis levels; the intradialytic half-life was 5.7 h. Vancomycin concentrations in serum exiting the dialyzer were 68% of those simultaneously entering the dialyzer at the beginning of dialysis. When polyacrylonitrile and conventional cellulose membranes were perfused in vitro with a recirculating solution of vancomycin, vancomycin concentrations fell to 39 and 91%, respectively, of the original concentration. The vancomycin concentration in the ultrafiltrate collected from the polyacrylonitrile membranes was only 23% of the original perfusate concentration. A significant decrease in the serum vancomycin concentration may occur during hemodialysis with newer high-flux dialyzer membranes. It appears that vancomycin binds to polyacrylonitrile membranes; this binding does not require the presence of protein and is affected by the pH of the perfusate.
منابع مشابه
Influence of cellulose triacetate hemodialyzers on vancomycin pharmacokinetics.
This study was designed to evaluate the pharmacokinetics of vancomycin during hemodialysis with cellulose triacetate (CT) high-flux dialyzers and to assess the influence of membrane surface area on intradialytic clearance. In a randomized crossover fashion, the pharmacokinetics of vancomycin were evaluated during dialysis with the CT 110 and CT 190 membranes. Six hemodialysis patients received ...
متن کاملVancomycin mass transfer characteristics of high-flux cellulosic dialysers.
BACKGROUND In comparison to conventional haemodialysis membranes, highly permeable membranes allow a broader spectrum of solute removal, including enhanced elimination of vancomycin (1448 Daltons). However, the mass transfer characteristics of vancomycin removal by highly permeable membranes have not been adequately assessed. An understanding of vancomycin's predominant dialytic mass transfer m...
متن کاملSuccessful Utilization of High-Flux Hemodialysis for Treatment of Vancomycin Toxicity in a Child
Vancomycin is routinely used for empiric antibiotic therapy in children. Higher-serum-concentration targets for serious infections are now being recommended. This recommendation may result in aggressive dosing with increased potential for toxicity. We report a case of a pediatric patient who developed vancomycin toxicity and associated oliguric renal failure who was treated effectively with hig...
متن کاملEffect of membrane permeability on survival of hemodialysis patients.
The effect of high-flux hemodialysis membranes on patient survival has not been unequivocally determined. In this prospective, randomized clinical trial, we enrolled 738 incident hemodialysis patients, stratified them by serum albumin < or = 4 and >4 g/dl, and assigned them to either low-flux or high-flux membranes. We followed patients for 3 to 7.5 yr. Kaplan-Meier survival analysis showed no ...
متن کاملProtein-leaking membranes for hemodialysis: a new class of membranes in search of an application?
A new class of membranes that leak protein has been developed for hemodialysis. These membranes provide greater clearances of low molecular weight proteins and small protein-bound solutes than do conventional high-flux dialysis membranes but at the cost of some albumin loss into the dialysate. Protein-leaking membranes have been used in a small number of clinical trials. The results of these tr...
متن کامل