Problems of the human body model and electrostatic discharge part 1: discharge from LSIs held by a charged person
نویسندگان
چکیده
The nanosecond transient response between a pin of a large-scale integrated circuit (LSI) held by a charged person and the ground plane showed a very sharp impulse and high peak current. This response could not be represented using the human body model (HBM), and it was caused by the parasitic capacity between an inner conductor in the LSI and the ground plane. However, the conventional HBM tester could not control the low capacitance. Consequently, the machine model (MM) using a low capacitance or the charged device model (CDM) with low device capacitance should be used. Moreover, the capacitanc of charged objects including LSIs can be determined by a Coulomb meter. Practical use of these data will give us the methods to prevent electrostatic discharge troubles for quarter-micron LSIs.
منابع مشابه
ارزیابی خطر تخلیه بار الکترواستاتیک و راهکارهای کاهش آن
The investigation and identification of principles and basics for electrostatic discharge is one of the most important possibly hazards in the field of high- energetic materials and other industries, in order to prevent the risk of explosions, as well as to consider effective solutions to control and reduce these risks. In this paper, the principles and mechanisms of electrostatic discharge, it...
متن کاملESD-protective clothing for electronics industry – A new European research project ESTAT-Garments
Current standard test methods for the evaluation of the performance of modern ESDprotective clothing used in electronics industry do not measure correctly the effectiveness of the clothing to protect sensitive electronics from electrostatic phenomena. Therefore a new European research project – ESTAT-Garments – was started in early 2002. The main objective of this three-years project (2002-2005...
متن کاملExtraction and Comparison of the Discharge Process in a Teaching Hospital
Background and Objectives: Patient discharge process starts from the point of the initial order of the physician order and continues to the discharge time of a patient and the release of the bed that was allocated to him/her. Lengthening the patient discharge process is regarded as a negative factor in the management of beds; this lengthy process leads to delay...
متن کاملIntelligent Knowledge Based System Approach for Optimization of Design and Manufacturing Process for Wire-Electrical Discharge Machining
Wire electrical discharge machining (WEDM) is a method to cut conductive materials with a thin electrode that follows a programmed path. The electrode is a thin wire. Typical diameters range from .004" - .012" (.10mm - .30mm) although smaller and larger diameters are available. WEDM is a thermal machining process capable of accurately machining parts with varying hardness or complex shapes. WED...
متن کاملIntelligent Knowledge Based System Approach for Optimization of Design and Manufacturing Process for Wire-Electrical Discharge Machining
Wire electrical discharge machining (WEDM) is a method to cut conductive materials with a thin electrode that follows a programmed path. The electrode is a thin wire. Typical diameters range from .004" - .012" (.10mm - .30mm) although smaller and larger diameters are available. WEDM is a thermal machining process capable of accurately machining parts with varying hardness or complex shapes. WED...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -