Diagnostic accuracy of preoperative CT scanning of pituitary prolactinomas.

نویسندگان

  • S Marcovitz
  • R Wee
  • J Chan
  • J Hardy
چکیده

Between 1980 and 1985, 102 patients (84 women and 18 men) who had coronal CT scans of the sella turcica for suspected prolactin adenoma underwent transsphenoidal exploration. The CT examinations were performed with a fourth-generation EMI scanner (CT 7070), and reports of the preoperative CT examinations were compared with the findings at transsphenoidal exploration. The same neurosurgeon performed all the operations. In 97 patients distinct adenomas were found at surgery, among which were 36 macroadenomas (diameter larger than 10 mm) and 62 microadenomas (one patient had two coexisting microadenomas). All macroadenomas were identified correctly on the preoperative CT scans. Preoperative CT scans correctly localized 58 microadenomas in 57 of 62 patients, for a sensitivity rate of 91.9%; this included correct localization in four patients with recurrent microprolactinomas and in the one patient with two coexisting adenomas. Three patients in whom the adenomas were found in a location other than that reported on the preoperative CT scan were considered to have false-negative scans for the purpose of statistical calculations; two other false negatives occurred in patients whose scans had been interpreted as entirely normal and who were subsequently found to have adenomas at operation. Four patients had negative surgical explorations and the preoperative CT scan was correct in one, for a specificity of 25%. The overall accuracy rate was 92.1% for the entire group of patients and 87.7% for the subgroup of microadenomas. In our experience, coronal CT scanning has high diagnostic accuracy in patients with pituitary prolactinomas.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The diagnostic accuracy of preoperative CT scanning in the evaluation of pituitary ACTH-secreting adenomas.

Between 1980 and 1985, 35 patients (26 women and nine men) who had coronal CT scans of the sella turcica for suspected ACTH-secreting pituitary adenoma underwent transsphenoidal exploration. The CT examinations were performed with a fourth-generation EMI scanner (CT 7070). The reports of the preoperative CT examinations were compared with the findings at transsphenoidal exploration; in cases wi...

متن کامل

Diagnostic accuracy of preoperative CT scanning of pituitary somatotroph adenomas.

Between 1980 and 1986, 58 patients (23 women and 35 men) had coronal CT scans of the sella turcica for suspected growth hormone-secreting adenoma and underwent transsphenoidal exploration. The CT examinations were performed with a fourth-generation EMI scanner (CT 7070), and reports of the preoperative CT were compared with the findings at transsphenoidal exploration. The same neurosurgeon perf...

متن کامل

CT of the sella turcica after transsphenoidal resection of pituitary adenomas.

A retrospective review of 120 patients undergoing transsphenoidal surgery for pituitary adenomas revealed that computed tomography (CT) was less sensitive and less specific than hormonal methods in identifying residual functioning adenomas. However, CT was the only useful method of evaluating nonfunctioning tumors, including pseudo-prolactinomas. Enlargement of the pituitary stalk, when seen on...

متن کامل

Effects of preoperative bromocriptine treatment on prolactin-secreting pituitary adenoma surgery.

Pituitary adenomas are benign intracranial endocrine tumors, accounting for ~10% of intracranial tumors. The aim of the present study was to analyze the effects of preoperative treatment with bromocriptine on the surgical treatment and postoperative complications of prolactin-secreting pituitary adenomas (prolactinomas). Data from 102 patients whose prolactinomas were surgically treated between...

متن کامل

Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 9 1  شماره 

صفحات  -

تاریخ انتشار 1988